Uniteck UNISOLAR 20.24D Manual De Instrucciones página 34

Ocultar thumbs Ver también para UNISOLAR 20.24D:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
ANOMALIES, CAUSES, REMEDIES
Panel light off
while sun is
présent
!
34
Usual functionning:
Panel voltage lower than
battery voltage.
Usual functionning: no
sunlight (ex. night).
One or several cells of your
panel are hidden.
Battery overvoltage.
Battery connection problem
(cables, terminals...).
Solar panel current exceeds
the power rating of the solar
charge controller.
Solar panel disconnected, not
connected properly, or short
circuit.
www.uniteck.fr
The panel will start charging as
soon as the panel voltage is
higher
than
the
voltage.
The charge will resume as
soon as the light becomes
stronger.
Check if your panel is clean
and make sure none of the
cells are hidden.
Disconnect the solar panel
then check if the battery is not
in overvoltage or your
coupling voltage does not
exceed the accepted input
voltage of the solar charge
controller (12V/24V).
Check connections.
Make sure the power of the
panel/solar module is adapted.
Check connections (polarity
and connection).
battery

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Unisolar 20.24rm