PREVENTIVE MAINTENANCE & CLEANING
To clean air cap and fluid tip, brush exterior with a stiff bristle brush. If necessary to clean cap holes, use
a broom straw or toothpick if possible. If a wire or hard instrument is used, extreme care must be taken
to prevent scratching or burring of the holes, which will cause a distorted spray pattern.
To clean fluid passages, remove excess material from cup, then flush with gun wash solution. Wipe the
gun exterior with a dampened cloth. Never completely immerse in any solvent or cleaning solutions as
this is detrimental to the lubricants and life of the spray gun.
When replacing the fluid tip or fluid needle, replace both at the
same time. Torque to 18-20 Nm (160-180 lbs.in). Do not over
tighten the fluid tip. Use spanner supplied with the gun and check
with a torque wrench.
When removing air cap from retaining ring, do not remove the ring
seat (4) from the retaining ring (5). Damage to the parts may
occur. Simply wipe parts clean and reassemble with new or clean
air cap.
To prevent damage to fluid tip (2) or fluid needle (18), be sure to
either
1) pull the trigger and hold while tightening or loosening the fluid
tip, or
2) remove fluid adjusting knob (20) to relieve spring pressure
against needle collar.
SUCTION/GRAVITY CUP. Empty excess material and clean the cup. Make sure the vent holes in the
diaphragm and the lid are clear.