Operation Instruction – MIG Mode (continued)
4
Setting Up the Welding Wire
Release the drive roll pressure arm (11) by lifting up the pressure
arm adjustment knob (10).
Rotate the drive roll knob (13) counterclockwise to remove it (See
Figure 2
Figure 3.
. and
Check your drive roll (14) size. Ensure it matches with your
welding wire size.
NOTE: Drive roll (14) has two grooves and each groove has a
different size. Make sure you are using the right size.
Place the drive roll knob (13) back and rotate clockwise to tighten
it.
Before inserting your wire into the wire feeder, ensure your wire
end is straight. Cut the bent end with wire cutter if necessary.
Feed your wire into the wire inlet guide tube (12) of the wire
feeder and line the wire up with the groove of the drive roll. Push
the wire across the inner drive roll groove into the other side of
the wire feeder.
Pull the pressure arm adjustment knob (10) back and lock it by
pushing the drive roll pressure arm (11) down.
Remove the nozzle from the end of the MIG/ ux core MIG gun.
NOTE: Metal nozzle is for MIG gun; non-metal nozzle is for ux
core MIG gun.
Remove the contact tip at the tip of the gun by unscrewing in
counterclockwise direction.
Plug the welder into power source.
For 120V: Switch voltage switch (Q) to 120V, use a 240V to 120V
adapter.
For 240V: Switch voltage switch (Q) to 240V, connect to 240V
power source.
Switch the ON/OFF switch (O) to ON. Push the welding mode
switch button (K) until MIG LED turns on. Ensure you are not
pointing the MIG/ ux core MIG gun to yourself and any other
bystanders.
Press the trigger on the MIG/ ux core MIG gun. Feed the wire
continuously until at least one inch of the wire extends out of the
gun.
Check if the drive roll is feeding the wire properly. If the drive roll
is slipping on the wire, increase pressure on the pressure arm
adjustment.
Check the contact tip and ensure it matches the welding wire.
Install the contact tip back to the MIG/ ux core MIG gun.
Attach the nozzle back to the gun.
Cut off the over-extended wire that sticks out of the ux core gun
if needed.
).
10
12
.
Figure 3
(i) Locked Wire Feeder, (ii) Released Drive Roll
Pressure Arm, (iii) Removed Drive Roll Knob