Lift Lockout/Tagout Procedure - Forward Lift MCH13 Guía De Instalación, Operación Y Mantenimiento

Sistemas de elevador de columnas alimentación con cc de 24 v
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Purpose
This procedure establishes the minimum requirements for the lockout of energy that could cause injury to personnel by the
operation of lifts in need of repair or being serviced. All employees shall comply with this procedure.
Responsibility
The responsibility for assuring that this procedure is followed is binding upon all employees and service personnel from
outside service companies (i.e., Authorized Installers, contactors, etc.). All employees shall be instructed in the safety
significance of the lockout procedure by the facility owner/manager. Each new or transferred employee along with visiting
outside service personnel shall be instructed by the owner/manager (or assigned designee) in the purpose and use of the
lockout procedure.
Preparation
Employees authorized to perform lockout shall ensure that the appropriate energy isolating device (i.e., circuit breaker,
fuse, disconnect, etc.) is identified for the lift being locked out. Other such devices for other equipment may be located
in close proximity of the appropriate energy isolating device. If the identity of the device is in question, see the shop
supervisor for resolution. Assure that proper authorization is received prior to performing the lockout procedure.
Sequence of Lockout Procedure
1)
Notify all affected employees that a lockout is being performed and the reason for it.
2)
Unload the subject lift. Shut it down and assure the disconnect switch is "OFF" if one is provided on the lift.
3)
The authorized lockout person operates the main energy isolation device removing power to the subject lift.
If this is a lockable device, the authorized lockout person places the assigned padlock on the device to
prevent its unintentional reactivation. An appropriate tag is applied stating the person's name, at least
3" x 6" in size, an easily noticeably color, and states not to operate device or remove tag.
If this device is a non-lockable circuit breaker or fuse, replace with a "dummy" device and tag it
appropriately as mentioned above.
4)
Attempt to operate lift to assure the lockout is working. Be sure to return any switches to the "OFF" position.
5)
The equipment is now locked out and ready for the required maintenance or service.
Restoring Equipment to Service
1)
Assure the work on the lift is complete and the area is clear of tools, vehicles, and personnel.
2)
At this point, the authorized person can remove the lock (or dummy circuit breaker or fuse) & tag and activate
the energy isolating device so that the lift may again be placed into operation.
Rules for Using Lockout Procedure
Use the Lockout Procedure whenever the lift is being repaired or serviced, waiting for repair when current operation could
cause possible injury to personnel, or for any other situation when unintentional operation could injure personnel. No
attempt shall be made to operate the lift when the energy isolating device is locked out.