DIRECT MOUNTING WIRING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
1. FIX DM BRACKET TO SQUARE POLE WITH BOLT, OPEN THE SIDE LID OF DM BRACKET, PULL THE WIRE
INTO JUNCTION BOX, AND CONNECT THE WIRE CORRECTLY. (FIGURE 7)
2. PUT THE CONNECTED WIRE INTO THE JUNCTION BOX, THEN COVER THE JUNCTION BOX. (FIGURE 8)
• NOTICE: ADJUSTABLE ANGLE IS 0-35°(FIGURE 7).
3. SAME AS ROUND POLE INSTALLATION, REMOVE THE SILICON PLATE WHEN INSTALL THE FIXTURE IN
ROUND POLE. (FIGURE 9)
7
FIXTURE
DM BRACKET
BOLT
POLE
CABLE
SQUARE
POLE
JUNCTION BOX
YOKE MOUNTING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
1. REMOVE THE BRACKET MOUNTING SCREWS ON THE FIXTURE AND RUN THE WIRES THROUGH THE
BRACKET. (FIGURE 10)
2. INSTALL THE BRACKET ON THE FIXTURE. (FIGURE 11)
10
EiKO Global | 18000 W 105th, Olathe, KS 66061 | (P) 1-800-852-2217
EiKO Canada | 81 King St, Barrie, Ontario L4N 6B5 | (P) 1-705-721-5189
8
DM BRACKET
ADJUSTING
SCREWS
SIDE LID
FIXTURE
SIDE LID
SQUARE POLE
11
9
DM BRACKET
FIXTURE
SILICON PLATE
ROUND POLE
(3" TO 5" DIAMETER)