VONROC PW507AC Traducción Del Manual Original página 9

Ocultar thumbs Ver también para PW507AC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
8. Turn on water and check for leaks.
9. Squeeze trigger to allow air to be expelled
though the pump and hoses, lock trigger as
shown in Fig. C5.
10. Plug in machine and turn on switch (2).
11. Unlock trigger as shown in Fig. C5 and use the
pressure washer.
Shut down
Never disconnect the high pressure hose
(4) from the machine while the system is
still pressurized.
ALWAYS turn off the unit's motor BEFORE
turning off the unit's water supply. Serious
damage could occur to the motor if the unit
is run without water.
1. Turn off the motor (push switch (2) to the off
position).
2. Unplug the unit from the power source.
3. Turn off the water supply.
4. Press the trigger of the gun (9) to depressurize
the system.
5. Disconnect the garden hose from the pressure
washer.
6. Engage the gun safety lock as shown in Fig. C5.
7. Wipe all surfaces of the unit with a damp clean
cloth.
Water supply
This unit is to be used with a cold-water
source only!
• Ensure that you have a suitable water supply
to feed the pressure washer. Check that all
connections are tight and there are no leaks in
the hose.
• The supply tap should be fully open (do not turn
on the pressure washer yet).
• Now depress the trigger (unlock trigger lock
fi rst) to let water pass through the unit and
expel any air.
• Turn on the pressure washer, once all the air
has been expelled and water has reached the
end of the lance.
WWW.VONROC.COM
Adjusting the nozzle (Fig. D)
• Water may be sprayed out of the nozzle either
linearly or in a fan shape. Turn on the pressure
fi rst, and then adjust the nozzle.
5. MAINTENANCE
Before cleaning and maintenance, always
switch off the machine and remove the
mains plug from the mains.
Clean the machine casings regularly with a soft
cloth, preferably after each use. Make sure that
the ventilation openings are free of dust and
dirt. Remove very persistent dirt using a soft
cloth moistened with soapsuds. Do not use any
solvents such as gasoline, alcohol, ammonia, etc.
Chemicals such as these will damage the synthetic
components.
Water inlet fi lter (Fig. A)
The water inlet fi lter (3) must be inspected
regularly, so as to avoid blockage and restriction of
the water supply to the pump.
Cleaning nozzle (Fig. A, E)
When the nozzle is clogged, it may cause failure.
The nozzle can be cleaned by inserting the
'cleaning pin' (13) into the tip to remove fi lth.
Storage and frost protection
The high pressure cleaner and accessories that are
not completely drained can be destroyed by frost.
Completely drain the high pressure cleaner and
accessories and protect them against frost.
Keep the high pressure cleaner in well-ventilated dry
premises with temperature not going below +5
MALFUNCTION
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
1. When switched on, the machine will not start
working.
• Plug is not well connected or electric socket is
faulty.
• Check plug, socket and fuse.
• The mains voltage is lower than the minimum
requirement for start up.
EN
C.
°
9

Publicidad

Tabla de contenido
loading

Tabla de contenido