Description Of The Components - Cembre B70M-P36 Manual De Uso Y De Mantenimiento

Bomba hidraulica a bateria
Ocultar thumbs Ver también para B70M-P36:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2. DESCRIPTION OF THE COMPONENTS

The part reference includes the following (See Fig. 1):
(A) FLEXIBLE HOSE: length 3 m (9.75 ft) specific for high pressure; provided with automatic quick
couplings; enables connection of the hydraulic head to the pump
(B) RUCKSACK: made from sturdy fabric, allows users to store and transport the pump and acces-
sories.
(C) SHOULDER STRAP: allows users to easily transport and comfortably carry the pump during
all work phases; to be connected to the rings (1).
(D) ERCH REMOTE CONTROLLER: ergonomically designed with a comfortable grip even while
wearing work gloves. provided with a 3 m connection cable, it allows users to control the
pump by two push-buttons:
- GREEN button to activate the pump with a pulse (starting from the display off ) and to activate
the pump motor.
- RED button to oil discharge: for returning the oil to the pump tank at any time.
(E) USB CABLE (Ref. to § 6)
(F) ASC-ULTRA BATTERY FAST CHARGER (diff ers depending on the pump version): for recharging the
batteries supplied; has "AIR COOLED" charging technology and a processor for managing
charging cycles.
To use, carefully follow the instructions in the battery charger user manual.
(G) CB3662L RECHARGEABLE BATTERY: 36 V - 6.2 Ah high capacity Lithium Ion battery.
The battery is equipped with LED indicators that indicate the
remaining battery life at any time by pressing
the adjacent button (C):
4 LEDs illuminated: fully charged
2 LEDs illuminated: 50 % capacity
1 LED fl ashing: minimum charge, the battery is
almost depleted and needs to be charged.
With the battery inserted into the tool, the remain-
ing battery life can also be checked on the display,
via touch button selection (Ref. to § 4).
The screen shown alongside indicates that the battery voltage has
dropped below a minimum safety threshold; under these conditions
the tool will not start, and it is necessary to recharge or replace the battery.
Batteries are supplied with a charge ≤ 30%. To maximise energy level, it is necessary to
fully recharge them before use. Charge the battery by following the instructions pro-
vided in the battery charger manual, approximately 50-60 minutes are required to charge a
fully depleted battery with ASC ULTRA fast charger. Only use the battery charger supplied with
the pump.
9
C
max.
min.
BATTERY
BATTERY
BATTERY

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

B70m-p36aB70m-p36eB70m-p36tB85m-p36

Tabla de contenido