8. The generator and its protections:
8.1 Electrical warnings before use.
WARNING: Ensure the installation of the ground wire. If you have doubts,
please, call your electrician.
WARNING: Never connect directly the voltage output of the generator to a
building or a house (even when there is a circuit breaker for the main circuit). The
return of the main circuit will shock with the generator output, which will do serious
damages to the generator or even a fire.
WARNING: Do not connect the generator in parallel with other generators in
order to add powers. The generators will be damaged and there will be a high risk
of fire.
NOTE: When an extension cable is required, you have to ensure its good
quality and proper section (ask to your electrician):
Cable length 60m: minimum cable section 2mm
Cable length 100m: minimum cable section 2.5mm
NOTE: Equipment that has an electric motor (compressors, water pumps,
saws, etc.) requires up to 3 times more power during the starting. For example, a
500W water pump requires 1500W to start up.