Regular safety checks
To help you fulfil the national/international requirements and to avoid malfunction and risk for in-
juries, we have provided the following checklist.
Do not use the operator if repair or adjustment is necessary.
Disconnect supply
Activate your operator and check visually, fastening and any damage of
operator
1
arm system
2
cables
3
hinges
5
door and glass
6
Also inspect your operator and check visually for
sharp edges on the door leaf and door frame (if any)
condition of door seals
finger protection
9
and finally that the complete door runs properly and closes slowly in a smooth way
Set the mode selector to OFF and check that the operator and electromechanical lock (if fitted)
work together. Also check that the lock
Activate the manual activation units
has opened appropriately while you pass the entrance/exit.
Then proceed with the automatic activation units
Check the safety sensors
door must not hit you when opening nor when closing.
If you are unsure of which type of sensor you have, please contact your
ASSA ABLOY Entrance Systems representative.
Escape
doors
Fire
doors
=
Take appropriate measures.
=
Contact your ASSA ABLOY Entrance Systems representative. For contact information, see last page.
10
14
when cleaning or other maintenance is to be carried out.
Daily Action
8
10
really secures the door.
11
, if any, and walk towards the door. Check that the door
13
if any, by standing in the swing path and activate the operator. The
Set the programme selector in AUTO mode. Push the door manually
in escape direction and make sure that no object or function will
prevent the door from opening. Also make sure the escape route is
free for use.
Let the door close after an impulse ensuring nothing prevents the
door from closing and locking (if regulations require it).
Issue 2019-06-28
7
12
in the same way.
If problem
occurs
1009214-multi-8.0