The recommended installation height of the COLORADO is 1.8m - 2.4m (71" - 95") from the floor. The lower
the heater is positioned, the more intense the heat.
Under no circumstances is the COLORADO to be installed at less than 1.8m (71") from the floor.
Consideration should be given to any temporary or occasional additions such as stages or platforms and
adjusted accordingly. For outdoor use, or other areas with air movement/wind the directional Infrared
spread may reduce by 1/3 to 1/2. In all locations, ensure hot parts are not touched accidentally.
Wall mount swivel brackets are provided with the heater which has been specifically designed to allow this
product to be fitted to a wall with adequate clearances at the back of the unit. Do not mount the heater
with any other bracket except those provided.
The sides and ends of the heater must always be at least 300mm (12") away from the nearest wall, ceiling
or other structure.
INSTALLATION:
Diagram 1: Bracket Assembly
Using the brackets as a template, mark and drill 4 x 8mm holes in the wall. Insert the plugs into the
wall and fit the brackets, washers, spring washers and nuts over the exposed threaded ends.
Tightening the nuts will force the plug end to expand in the wall and form a secure mounting for the
heater.
Fit the opposite bracket to the back of the heater before then inserting and tightening the bolt and
nut for each hinge.
Diagram 2: Correct Wall / Ceiling Position
Mounting Hardware Includes:
• 4 x bracket pieces - fit together
to form 2 brackets with a central
pivot. The protruding blade on
each bracket fits over the circular
end of the opposing bracket to
ensure the correct pivot angle.
• 4 x M6x60 masonry expansion
bolts (for fitting brackets onto
wall).
• 2 x wing nuts to fit brackets onto
the rear of the heater.
• 2 x small bolts and lock nuts (to
form the pivot on the brackets).