Electrical Information; Mounting Position - Herschel COLORADO 2500R Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
12. All operators shall only switch on/off the appliance provided that it has been placed or installed in its
intended normal operating position and they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved. Children shall not plug in,
switch on or regulate the appliance or perform user maintenance including cleaning.
DO NOT
13.
leave the heater operating unattended.
NEVER
14.
place hands under the heating element during operation.
IMPORTANT:
15.
SAVE THESE INSTRUCTIONS.
WATER INGRESS PROTECTION:
Herschel COLORADO is rated to a standard IP55. Suitable for outdoor use.
Installation in potentially wet or humid rooms such as bathrooms must be carried out by a suitably qualified
installer and comply with local electrical safety requirements.
If in doubt, do not install. Herschel Infrared Ltd shall not be liable for any loss, damage or injury caused or
resulting from inadequate fitting or incorrect placement of heaters close to water sources.

ELECTRICAL INFORMATION:

The Herschel COLORADO may be plugged in to a waterproof socket. Any extension lead used must have
sufficient capacity to carry the current required by the heater as show in in Table 1. All plugs, sockets and
switches intended for use outdoors must have an appropriate water ingress protection.
Alternatively the plug can be removed and the unit connected to fixed mains wiring. Fixed wiring
installations must only be carried out by competent persons or a qualified electrician according to national
regulations and the unit must be earthed. The electrical supply to the unit should be provided by connecting
to a current protection device suitable for the electrical rating of the unit in accordance with Table 1 and
providing disconnection in both poles. All fixed wiring must have sufficient capacity to carry the current
required by the heater.
Always disconnect the heater from the power when not in use.
Table 1. Electrical Specification
Model
COLORADO
2500R
The mounting position of the unit must ensure that any mechanical damage to the flexible cable is unlikely.
Any exposed flexible cable is to hang down (not tied UP) and must have adequate clearance from the heater
to prevent scorching or damaging the cable. Colour coding used in the supplied mains cable: BROWN wire
is to be connected to LIVE ('L'), the BLUE wire to NEUTRAL ('N') and the GREEN/YELLOW wire to EARTH ('E').

MOUNTING POSITION:

Ensure supply voltage does not exceed 245 Volts.
Rated
Voltage
Power
2500W
220-240V
Current
Frequency
10.9A
50/60Hz
ENGLISH
Fuse
(Minimum)
13A

Publicidad