2. DESCRIPTION OF THE APPLIANCE (Fig. 8)
1.
Intake air filter
G
2.
Air receiver
3.
Tank condensate drain valve
B
4.
Air pipe
5.
Quick coupling
6.
Pressure gauge (indicates the tank pressure)
7.
Reel
8.
Switch I/O (ON/OFF)
9.
Power cord
10. Safety valve
3. PACKAGING CONTENTS LIST
● Air compressor
● Assembly instruction sheet
● Rubber Spacers (4)
● Instruction manual and other documents

4. SCOPE OF USE

The compressor is designed for generating compressed air for tools
operated by compressed air.
Please note that our equipment has not been designed for use
in commercial, trade or industrial applications. Our warranty will
be voided if the machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The machine is to be used only for its prescribed purpose. Any other
use is deemed to be a case of misuse. The user/operator and not
the manufacturer will be liable for any damage or injuries of any kind
caused as a result of this.
5. POINTS TO NOTE WHEN SETTING UP
THE COMPRESSOR
● Examine the machine for signs of transit damage. Report any damage
immediately to the company which delivered the compressor.
● The compressor should be set up near the working consumer.
● The use of extension cords is not recommended.
● Make sure the intake air is dry and dust-free.
● Do not set up the compressor in damp or wet rooms.
● The compressor may only be used in suitable rooms (with good
ventilation and an ambient temperature from +5°C to +40°C). There
must be no dust, acids, vapors, explosive gases or inflammable
gases in the room.
● The compressor is designed to be used in dry rooms. It is prohibited
to use the compressor in areas where work is conducted with
sprayed water.
Attention!
This compressor shall only be used fixed to a wall suitable to
support its weight; it is forbidden to use the compressor in any
other configuration.
6. INSTALLATION
After removing the compressor from the packaging and checking its
integrity, make sure that all the components listed in the "packaging
contents list" are present inside the packaging.
Before starting the installation of the compressor, it is necessary to
obtain the materials and/or tools shown in figure 1 (NOT supplied),
more precisely:
– Measuring tape,
– Adhesive tape,
– Scissors,
– Spirit level,
– Drill/screwdriver,
– Cross head screwdriver,
– Screws (4),
– Expansion plugs (4).
Warning!
For fixing on solid or concrete walls, use screws and expansion
plugs. For fixing on any other surface (previously verify that
the wall can support the weight of the compressor), purchase
appropriate screws and plugs.
For fixing, it is recommended to use the help of a second person.
Choose the position where the compressor shall be mounted in a way
that the appliance has enough space to rotate more than 170° degrees
and that the compressed air hose can be easily reached.
To obtain good ventilation and effective cooling, it is important that the
compressor is at least 50 cm away from any wall and/or obstacle (fig.
2), with the exception of the wall itself where the compressor is fixed.
6.1 Wall fixing
Observe the specifications indicated in this manual (figures 3, 4 and
5).
● Use the instructions sheet (supplied) as a template to
mark the points where to make the holes for fixing (fig. 3).
Remove and keep the sheet for future consultation and/or reuse.
● With an 8 mm bit, drill four holes in the wall (fig. 4), and insert the
expansion plugs (fig. 5).
● Insert the screws, taking care to previously insert the rubber spac-
ers (fig. 5).
● Almost fully tighten the screws (fig. 6 - phase I).
● Place the compressor in correspondence with the four screws, then
hang it taking care to insert each slot of the compressor frame onto
the screws: as shown in fig. 6 - phase II.
● Gently lower the compressor, so that all four screws can be inserted
into the narrow shape of the slot, as shown in fig. 6 - phase III.
● Fully tighten the four screws (fig. 7).
7. SETTING
7.1 Connection to the network
The compressor is equipped with a power cord with shock-proof plug.
Insert the plug of the power cord into a socket suitable regarding
shape, voltage and frequency and compliant with current regulations.
Before commissioning, make sure that the mains voltage corresponds
to the operating voltage indicated on the data plate of the appliance.
Make sure the ON/OFF switch is not in the I (ON) position. Power
cords that are too long as well as extensions, cable reels, etc. cause a
voltage drop and can prevent the engine from starting. At low tempera-
tures below +5°C, starting the engine can be more difficult.

7.2 Start-up and use

● Check the compliance of the compressor plate data with the real data
of the electrical system; a voltage variation of ± 10% with respect to
the nominal value is admitted.
● Connect the desired pneumatic tool to the quick coupling (ref. 5).
– The reel (ref. 7) is built with an automatic locking mechanism
that allows the hose (ref. 4) to be stopped at the desired
length.
Never let the hose rewind in an uncontrolled way.
– The locking system produces a metallic sound during unwind-
ing and winding; it is not a sign of a defect.
If the noise changes after numerous applications and/or in
case of problems with the mechanism, contact the service
centre.
– Unwinding the hose: carefully remove the hose from the
housing; after unwinding the necessary length of hose, loosen
the grip slightly, in this way, when a "CLICK" is heard, the lock
is inserted (fig. 9).
Ensure that the hose is locked before releasing the grip.
– Rewinding the hose: loosen the lock by pulling the extension
hose outwards (fig. 10). Let the hose rewind in a controlled
way, accompanying it until it completely returns to the reel.
● Insert the power cord plug into a suitable socket, making sure that the
I/O switch on the compressor is in the switched off position "O" (OFF).
● At this point the compressor is ready for use.
● Use the I/O switch to start the compressor pumping air and putting
it through the delivery hose into the tank.