Br Electrical Connection; Inserting The Remote Control Battery; Thermostatic Probe; External Room Thermostat - EQUATION L2 OPEN 9 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
EN
ELECTRICAL CONNECTION

INSERTING THE REMOTE CONTROL BATTERY

THERMOSTATIC PROBE

The room temperature is detected thanks to the probe located on the
back of the device. This probe must be deployed so as not to be affected
by the temperature of the stove.

EXTERNAL ROOM THERMOSTAT

The stove is equipped with a connector for the connection of an exter-
nal thermostat. This thermostat allows you to manage the functioning
of the stove through the wall thermostat rather than through the probe
at the back of the stove. The thermostat must be of the "dry contact"
type to turn on or turn off the stove according to heat needs.
Configure this thermostat to manage a pellet stove.
Setting the stove to receive information from the external thermostat
For the external thermostat to be recognized by the stove, the technical menu parameter CP09 must be set to On.
• Press
several times to display
menu 04 (technical menu)
• Press
several times to display
the CP09 parameter

SETTING THE BEHAVIOR OF THE THERMOSTAT

The thermostat can behave in two different modes:
• Eco mode (StoF)(by default): when the set temperature is reached, the stove goes down to power 1 and stays on this power without
switching off.
• Eco Stop mode (St01...): when the set temperature is exceeded, the stove goes down to power 1 then switches off.
230V~
50Hz
CR 2025 - 3V
1
Connector for
thermostat
Connector for
maintenance
• Press
to confirm
• Press
to activate the external
thermostat
• Press
to confirm
58
2
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

83670255

Tabla de contenido