Installation Instructions; Technical Specifications - ADF LINEA Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2- Installation Instructions

Technical Specifications

Antonino Dias Fernandes Lda., declares under its responsibility that the equipment has been designed and manufactured
according to (EU Reg. No. 305/2011), Construction Products Regulation, being approved with the CE conformity mark;
Uni.
Nominal Heat
kW
Output
Energy
%
Efficiency
Vol.%
CO content
Average
temperature of
ºC
combustion
products
Flue gas mass
g/s
flow
Chimney draft
Pa
at nominal
heat output
mm
Flue dimension
Minimum
distance to
mm
combustible
materials
Maximum
mm
Firewood
Width
Max
kg
recommended
firewood load
kg
Weight
Recommended
fuel
* "box" weight only
Note:
The compartment below the combustion chamber of the freestanding appliances should not be used as a fuel tank.
Freestanding heaters shall be laid on a non-combustible non-flammable surface (if it is stone or other equivalent at least
6cm high) where the ends extend at least 80cm from the front of the appliance.
.
70
85
8,1
8,9
84
83
0,05
0,08
238
254
6,0
6,6
180
200
530
630
4
5
135*
153*
Apenas Lenha com humidade inferior a 20%
23
85
100
Duo
10,4
8,4
80
78
0,09
0,11
286
267
7,8
6,9
12
200
200
1500
830
630
6
5
180*
170*
100
Duo
9,8
75
0,12
300
8,2
200
830
6
204*