•
Installation and wiring must be carried out by a qualified professional to ensure proper operation and
safety. It is recommended that all safety regulations in force be complied with.
•
When installing the appliance, means must be provided for switching off the appliance in accordance
with the legislation in force. - Apply a cut-off switch on the fixed electrical system.
•
A minimum spacing of 3 mm between contacts must be observed in accordance with current
legislation
•
If the power cord is damaged, it must be replaced by a qualified professional as the power cord has
special technical characteristics for high temperatures.
•
Used cables should be insulated with silicone-insulated fiberglass sleeve for thermal insulation.
•
When installing Linea mandatory in the fireplace, air intake for fans with a minimum of 500 cm2
Piping
You will only be able to take advantage of the maximum efficiency of your appliance if the chimney is also
efficient. Before installing your appliance, make sure that the chimney is clean and unobstructed. If it is not
easy to verify, ask for a technician.
Both the height and the pressure drops in the chimney are directly related to their draw, so the pipe must
have the most rectilinear trajectory possible or if it is not possible, never use angles of more than 45º with
the vertical - In the first 2 meters of piping there should be no curves.
It is also ideal that the exhaust duct shall pass through the interior of the building thus ensuring better
thermal insulation, so as to avoid the unwanted condensations caused by temperature differentials, which
may, sooner or later, deteriorate the system. The piping should preferably be in stainless steel and
thermally insulated throughout its length in order to avoid condensation phenomena that will deteriorate
the installation (It is not recommended the use of exterior flue ducts or ducts without insulation).
The chimneys must have individual
smoke
ducts
and
recommended that you do not group
several chimneys together in collective
ducts. The exhaust ducts must have a
constant section from the exit of the
appliance to the evacuation of the fumes
to the atmosphere.
it
is
strongly
26