Ignition; After Firing - ADF LINEA Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3- Instructions for daily use
Note:
Check "Wood – Utilization" (pg.21), max load (pg.23), combustion control (pg.29) and "Important
Recommendations" (pg.19)

Ignition

1.
It is extremely important to thoroughly examine the chimney and to make sure it is clean and
unobstructed in order to use the appliance for the first time, or after a long stop. If it is not easy to do
so, ask for a technician.
The appliance was designed to work intermittently, with fuel load intervals ranging from 45 to 60
minutes.
2.
Completely open combustion air control. Put an easily flammable combustible material (firelighters,
pine cones, etc...) on the base of the furnace.
3.
On top of what was mentioned before, stack small logs of dry wood, horizontally (about 1kg).
4.
Keep the door slightly open, allowing the amount of air needed for a quick and efficient ignition,
keeping the combustion air control fully open.
5.
After 5 minutes close the door and reduce the combustion air control to reduce the combustion air
intake
6.
Let it burn to create the first embers.
Note: In the ignition, fine, dry wood should be used.

After Firing

1.
Open the door slowly, spread the embers evenly across the furnace base.
2.
Place the wood logs (approximately 1kg each) horizontally - do not overload the appliance - according
to your model check the maximum permissible load in the appliance characteristics table
3.
Choose a position in the combustion air control to produce a soft, long-lasting burn, avoid uncontrolled
burning.
Notes:
• Only reload with wood when the previous load has been fully consumed, do not overload the combustion chamber (Up to ½
height of the combustion chamber taking into account the maximum recommended load referred to on page 6)
• Even after frequent use, never make intense and prolonged burning. The performance will be minimal and could damage the
appliance and will lead to the consequent loss of warranty.
• •Excessive combustion does not necessarily translate into more heating power nor into an increase of efficiency. It may also
cause irreparable damage to the appliance if carried out for long periods of time
• •In the event of malfunction, immediately extinguish combustion by closing the fuel inlet control and the smoke control,
causing the fire to extinguish by itself due to lack of oxygen. Expose the problem to our services and / or agents to be resolved.
• In case of adverse atmospheric conditions that affect the draft of the chimney of the appliance its use is not recommended
• •This appliance was not designed to work with the door open. Do not open the door of the Heat appliance suddenly or with
the smoke control fully or partially closed, as the combustion chamber may overpressure, causing smoke or even flame out
into the room
30

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hayra

Tabla de contenido