CONNECTING AND LINKING THE RDNET SIGNAL
To enable remote control, connect the Data Input of the first subwoofer to the hardware interface (RDNet Control
2 or RDNet Control 8) using cables fitted with etherCON connectors. Then connect the Data Output of the first
subwoofer to the Data Input of the second one, and finally from the second subwoofer to the top. Power up the
speakers and make a "GoOnline" request in the AURORA NET software; the "Link" LEDs will confirm that they are
connected.
The "Active" LEDs will start flashing to indicate that there is data traffic.
FIFTY SUB 1
RDNet
Data In
RDNET
RDNET
CONTROL
CONTROL
3. REMOTE CONTROL
The AURORA NET software can be used to manage various parameters of the FIFTY TOP speaker and FIFTY SUB
subwoofer in real time.
In detail:
FIFTY TOP
•
Monitor the input and output signals
•
View if there is audio compression on the output signal and acoustic components
•
Attenuate the input signal
•
MUTE the driver and woofer separately
•
SOLO the woofer and driver separately
•
Monitor the temperature of the amplifier
•
Apply a high pass filter
•
Calibrate the speaker inclinometer
•
Save settings as presets for subsequent remote recall
•
Equalise the speaker
•
Add delay
Fifty Line
36
FIFTY SUB 2
RDNet
Data Out
Data In
FIFTY TOP
RDNet
Data Out
Data In
English
Data Out
Cod. 420120397 REV. 1.0