BIR 01- _ _ _ _ -K15AL _-000S92
Inductive Rapid Positioning System
About this guide
This guide provides all the information required for the
installation and connection of the BIR inductive rapid
positioning system with IO-Link interface and analog
current or voltage interface.
It applies to the following models:
BIR 01- _ _ _ _ -K15AL _-000S92
Intended use
The BIR inductive rapid positioning system, together with a
machine controller (e.g. PLC), comprises a position
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Proper function according to the specifications in the
technical data is only assured when the product is used
solely as described in the user's guide and the respective
documents as well as in compliance with the technical
specifications and requirements and only with suitable
original Balluff accessories.
Otherwise, there is deemed to be unintended use.
Unintended use is not permitted and will result in the loss
of warranty and liability claims against the manufacturer.
Reasonably foreseeable misuse
The product is not intended for the following applications
and areas and may not be used there:
In safety-oriented applications in which personal safety
depends on the device function
In explosive atmospheres
In food applications
16
27
2)
13.3
23.2
~80
1)
Mounting clamps
BAM MC-TL-048-PF-1
www.balluff.com
Measuring length
1)
Target BAM TG-IR-036-A
~250
~250
1) not included in scope of delivery
15
2) unusable area
Other applicable documents
A comprehensive user's guide and additional information
about this product can be found at www.balluff.com on
the product page.
Safety notes
Activities such as installation, connection and startup
may only be carried out by qualified personnel.
Qualified personnel are persons whose technical
training, knowledge and experience as well as knowledge
of the relevant regulations allows him to assess the work
assigned to him, recognize possible hazards and take
appropriate safety measures.
The operator is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the product will not result in hazards to persons
or equipment.
The product must not be opened, modified or changed. If
defects and unresolvable faults occur in the product, take
it out of service and secure against unauthorized use.
Dimensions and function
To determine the position of a system component, a target
is connected to the component directly or indirectly
depending on the type and moved along the sensor. The
position of the system component is determined parallel to
the position monitoring of the target.
In the BIR inductive rapid positioning system there is a
transmitter/receiver sensor element, protected by an
extruded section made of aluminum and a very resistant
plastic (PBT).
The target contains a resonant circuit and is inductively
coupled to the BIR.
26
2)
13.8
2.8
~80
LED
LED
35
50
68
english