Water full alarm
Under normal use, the unit can evaporate the condensed water automatically, and little of water will be
accumulated in the inner water tray.
As soon as the condensed water collected in the inner water tray reaches a certain height, a water full alarm
will be sent out: the water full indicator light will illuminate, and the digital display will show "E2" code approx.
5 minutes later.
Thus, when the water full alarm occurs, please drain the water in the water tray. Remove the rubber boot and
then the rubber stopper from the drain port at the bottom of the unit, and drain out the water.
Continuous drainage
Continuous drainage can be used to avoid the water full alarm disturbance. Prepare a drain hose. Connect it to
the drain port at the middle of the unit and drain water into a bucket or floor drain. The unit can also work
well.
-
If you plan to leave this unit unused for a long time, please use both of the drain ports to drain out the
water.
-
If the condensed water accumulates fast and leads to water full alarms shortly, the splash motor inside the
machine may be damaged. In this case, please contact our service department at www.emerio.eu/service
CLEANING AND MAINTENANCE
Before cleaning, be sure to disconnect the appliance from any electric supply outlet.
Do not use gasoline or other chemicals to clean the appliance.
Do not wash the appliance directly.
Air Filter
If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks.
-
Pull out the air filter from the bottom to take it off the appliance.
-
Clean the air filter with neutral detergent in lukewarm water (40℃) and dry it up in the shade.
-
Insert the air filter back.
Clean the Surface
First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth.
TROUBLESHOOTING
Troubles
Appliance does not
start when pressing
the power button
Not cool enough
Noisy
Possible Causes
Water full indicator light blinks, and
water tray is full.
Room temperature is lower than the
setting temperature.
The doors or windows are not closed.
There are heat sources inside the room.
The hot air exhaust hose is not
connected or blocked.
Temperature setting is too high.
Air inlet is blocked.
The ground is not level or not flat
enough.
The sound comes from the flowing of
the refrigerant inside the appliance.
Solutions
Remove the rubber stopper to dump
the water out from the drainage outlet.
Reset the temperature.
Make sure all the windows and doors
are closed.
Remove the heat sources if possible.
Connect or clean the hot air exhaust
hose.
Reset the temperature.
Clean the air inlet.
Place the appliance on a flat, level
surface if possible.
It is normal.