SC 20 • Operating Manual
FAULTS AND TROUBLESHOOTING
Machine does not start up
• Check the power supply to be connected to the electric network.
• Check the main switch. Replace if needed.
Low stripping capacity
• Check the edge of the blade. Worn out blade significantly decreases the stripping capacity.
Replace if needed.
Noises from the oscillating head
• Check the bearing. Defective bearing must be replaced before the next use.
• The machine/blade jumps from the floor when used. Check the blade angle. It may be too
shallow. Using an angle that is too steep may cause damage to the floor. Set the blade angle
carefully.
TECHNICAL SPECIFICATIONS
General
Serial number
Weight
Dimensions
Working width
Distance to wall
Electric motor drive
Size
Power
Speed
Available as
Design
Protection type
Motor protection switch
Sound pressure level
Acoustic power level
Vibration level
14
aaa.bb.cc.xyz
aaa = Type, bb = Model year,
cc = Month, xyz = consecutive
35.9 kg
372 x 1008 x 885 mm
200 - 230 mm
88 mm (basic blade)
90 L
1.5 kW
2800 RPM
115 V / 50 Hz, 115 V / 60 Hz, 230 V / 50 Hz
B14
IP 55
25 A / 115 V, 13.5 A / 230 V
90.5 db(A)
98 db(A)
9.76 m/s
2
Faults and troubleshooting