Descargar Imprimir esta página

Comelit 20004606 Manual Tecnico página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
Warning
• This Comelit product was designed for use in the creation of security and home automation systems in residential, commercial or industrial settings
and in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the manuals / instruction sheets supplied with those products.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• Cut off the power supply before carrying out any maintenance procedures.
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system
created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided
in the manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for
systems, by qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and
warnings contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this
manual / instruction sheet at any time and without prior notice.
Home automation module with 2 inputs for direct connection of 2 control buttons and 2 outputs interlocked electronically from the
module with electromechanical relays of 2A max. 350W.
Suitable for control of automated openings such as motors for sunblinds or roller shutters with power consumption up to 350W.
The module outputs cannot be connected to direct current motors.
Power supply voltage
Consumption
Inputs
Outputs
TOTAL MAXIMUM LOAD: 2A - 230 Vac
Electromechanical motors for automated
openings, 230 VAC cosϕ ≥0.9
Electronic motors for Automated
openings, 230 VAC
BUS and power supply
Positioning
Approvals
Operating temperature
Storage temperature
Relative air humidity
Weight
Dimensions
* with access allowed only for support or servicing by qualified personnel.
The address of the module on the home automation BUS must be set using the SimpleProg software available to download free
of charge from pro.comelitgroup.com
Programming must be carried out by connecting the device to the BUS and sending the programming over this.
Specifications are subject to change without notice.
ART. 20004606
TECHNICAL CHARACTERISTICS
350 W - 1.5 A (with outputs
interlocked electronically from the
module)
350 W - 1.5 A (max. inrush current
12A for 20 μs) with outputs
interlocked electronically from the
module
ADDRESSING AND PROGRAMMING
24 Vdc ±5%
between 8,5 and 16 mA
I1
input 1
V+
24 v
I2
input 2
C
common
O1
output 1
O2
output 2
D
data BUS
+
+24 Vdc power supply
-
Power supply negative
On a DIN rail on a dedicated control panel or in a
junction box*
CE
0° to 40°C indoor use
-10° to +70°C
5 to 95% with no condensation
40 g
50 x 50 x 18.5 mm (1 DIN module)
3

Publicidad

loading