3.2.1. The operation modes of WZG 250B+
The red LED indicator blinks at the symbol of the selected power mode. Change mode by
pushing shortly the MODE button. One push will move the selection to the next one on the
list. The modes are:
Full power
Energy saving low power mode
Automatic day mode: Full power in day light and low power at night.
Automatic night mode: Full power at night and low power in day light.
No light
Stand by mode: fence not electrified
A longer push of the MODE button switched the energiser to the stand by mode. When you
switch on the energiser with a sort push of the MODE button, it will return to the mode that
was active when the energizer was put to stand by. IF you disconnect the battery, the
energizer will operate in the mode that was active before disconnecting the battery.
The light sensor for the automatic modes is located under the fence voltage LED bar. Dot not
cover the sensor! In all modes the energiser automatically adjusts the output according to the
fence voltage. Therefore the longest battery life will be reached with a short fence that has no
or little ground leaks.If the uppermost MODE LED lights for a longer time before starting
pulsing, the energiser may have an operation problem. Disconnect the battery, wait for a
moment and start the energiser again. If the situation repeats, deliver the energiser to service.
3.2.2. Voltage display of WZG 250B+
The energiser measures the fence voltage and blinks shortly the LED light that indicates the
fence voltage. (Approx. 7 kV green, 5 kV green, 3 kV yellow and 2 kV red, 1 kV = 1000 Volt).
If none of the LEDs is blinking, the fence voltage may be too low. Try selecting full power
mode, and if that does not help, check and repair the fence.