POWERinvert PRO | Pure Sine Wave Inverter
Operation
Switching On
1. Ensure that the inverter power on/off switch is in the OFF (0) position.
2. Plug the appliance into the AC output socket on the inverter, ensuring it does not exceed the maximum output power of the inverter.
3. Turn the power on/off switch to the ON (I) position.
4. The Power indicator will illuminate green and mains power will be available from the AC output socket(s).
On models fitted with a display the LCD screen will also illuminate.
LCD-Display and Indicators
Where fitted the LCD display provides additional information to help monitor and manage power from the inverter.
Information Mode
Various information modes are available by pressing
DC Voltage:
Input voltage available from the battery supply.
DC Current:
Input current being used from the battery supply in order to power the load.
**The optional Current Sensor must be fitted to enable measurement of input current.
AC Voltage:
Output voltage available from the AC outlets.
Output Wattage:
Output power being consumed by the connected loads.
Hours Remaining:
An estimate of time remaining before the battery will be depleted based on the current load.
***The optional Current Sensor must be fitted to enable measurement of hours remaining.
Setup Mode
The inverter can be configured by entering the setup mode.
• To enter Setup Mode press & hold
• Press
keys to select item then press
• Adjust setting using
• Press and hold
key to exit back to Information Mode.
Output Voltage:
Sets the AC output voltage. Only change if the application requires a different voltage for optimum performance.
Last Error Code: Allows the last error code to be viewed.
Battery Size:
Sets the Ah rating of the battery supplying the inverter.
The value is used when calculating input current and hours remaining in conjunction with the Current Sensor.
Indicator and Error Modes
Power:
Illuminates green to show the unit is switched on and power is available from the AC output socket(s).
Overload:
Illuminates red if the units has been overloaded due to excessive current or a short circuit.
Over Temperature: Illuminates yellow if the unit has overheated.
Audible Alarm:
An alarm sound will be heard if the unit has switched off due to a fault.
8
key.
, chosen setting will then flash.
then press
to set.
3
Output Voltage
4
RCD Test
5
Last Error Code
6
Battery Size
8
Power saving Mode
9
Low Voltage Cut-off
10
Output Frequency
buttons to move forward or backwards through the screens.
Setting
200/220/230/240V
N/A
N/A
90 – 540Ah (in 30Ah in steps
ON/OFF
9-5 – 11.0V (in 0.5V in steps)
50/60Hz
1
7
)
Default
2
230V
N/A
N/A
90Ah
ON
10.0V
50Hz