How to empty Shake Out Bag
1. Slide the clamp away from the top of
the bag.
2. Turn the cam latch to release the bag.
Hold the bag by the collar (bottom)
and shake. Reinsert the bag adapter
into the bag adapter retainer.
3. Push the bag collar up and forward so
the locator lug slides into the slot. Turn
the cam latch to lock the bag onto the
rivet.
How to maintain
How to replace a worn belt
Warning: Belt pulleys can become hot
during normal use. To prevent burns, avoid
touching the belt pulley when servicing the
drive belt.
1. Release cam locks and remove
bottom plate. Pull up on belt to rotate it
off of the motor pulley. Lift up on
brushroll and remove worn belt. Place
new belt around the brushroll. Align
brushroll pulley with belt guide (Fig. 3).
2. Ensure rubber end cap cover is
installed correctly (Fig. 4A). Align end
caps with slots in cleaner base. Push
brushroll into base.
3. Place lower side of belt into belt guide
and pull to stretch the belt around the
left side of the motor pulley. Rotate
pulley to secure the belt into the
groove. Replace bottom plate and
secure with the cam locks.
How to replace bristle strips
(some models)
4. Remove rubber end cap (A) from one
end. Unscrew locknut (B). Remove
end cap (C) – sleeve bearing brushroll
includes a shaft washer not shown.
Remove bearing retainer (D). Push
shaft (E) through opposite end. Pull
out worn bristle strip (F) with pliers.
Slide in new bristle strip of same
length (rounded end first.)
Fit track on either side of the bristle
strip into the brushroll slot. Replace
the second strip from opposite end of
brushroll.
5. Replace shaft. Align indentation on
bearing retainer with bristle strip on
both ends of brushroll. Reassemble
the remainder of brushroll and secure
into the base (Fig. 2).
4 www.sanitairecommercial.com
1
2
CAUTION
!
Turn off the switch and unplug the electrical
cord before maintenance.
Important: Improper installation of the
brushroll or brushroll belt could cause carpet
or cleaner damage.
1
Bottom metal plate
3
Belt groove
Brushroll
4
B
C
A
5
3
2
F
E
D

Publicidad

loading

Este manual también es adecuado para:

Sc800 serie