Level switch with heat exchanger for very low operating temperatures (O-rings IP66/IP67)
TDI..., TDIN..., TII...,
5TDI..., 5TDIN..., 5TDII..., etc.
TDIE9..., TDINE9..., TDIIE9...,
5TDIE9..., 5TDINE9..., 5TDIIE9...,
etc.
Level switch for submersible application with cable (IP68)
U...I..., U...IN..., U...II...,
5U...I..., 5U...IN..., 5U...II..., etc.
U...IE9..., U...INE9..., U...IIE9...,
5U...IE9..., 5U...INE9..., 5U...IIE9...,
etc.
The rated cross-section of the conductor to be considered here must be at least 0.5 mm².
Connection cables may not be bared for a distance of more than 3 mm from the terminal screw. Wire
end ferrules must always be used.
6.
Installation and initial start-up
During installation, the correct operating position must be observed.
For side mounting, observe the «Top» arrow on the type plate.
www.trimodbesta.com
Limits
Ambient
proximity switch
temperature
T
T
i
A
-25°C to 100°C
The combinations of the maximum values are to be avoided!
Limit value combinations according to temperature diagram
3081-053EN in the appendix 7
Limits
Ambient
proximity switch
temperature
T
T
i
A
-40°C to 100°C
The combinations of the maximum values are to be avoided!
Limit value combinations according to temperature diagram
3081-058EN in the appendix 8
Limits
Ambient
proximity switch
temperature
T
T
i
A
-25°C to 150°C
-25°C to 80°C
The combinations of the maximum values are to be avoided!
Limit value combinations according to temperature diagram
3081-054EN in the appendix 9
Limits
Ambient
proximity switch
temperature
T
T
i
A
-40°C to 150°C
-30°C to 80°C
The combinations of the maximum values are to be avoided!
Limit value combinations according to temperature diagram
3081-059EN in the appendix 10
14 │ 46
Operating
temperature
T
0
-10°C to 80°C
-196°C to 270°C
Operating
temperature
T
0
-10°C to 80°C
-196°C to 270°C
Operating
temperature
T
0
-25°C to 80°C
Operating
temperature
T
0
-30°C to 80°C
LTB008X │ 2023/01