5. Commissioning, operation
5. Commissioning, operation
Personnel: Skilled personnel
Tools: Screwdriver, open-ended spanner
EN
WARNING!
Physical injuries and damage to property and the environment
caused by hazardous media
Upon contact with hazardous media (e.g. oxygen, acetylene, flammable
or toxic substances), harmful media (e.g. corrosive, toxic, carcinogenic,
radioactive), and also with refrigeration plants and compressors, there is a
danger of physical injuries and damage to property and the environment.
Should a failure occur, aggressive media with extremely high temperature
and under high pressure or vacuum may be present at the instrument.
▶
▶
Please observe the following general requirements when mounting and operating the
instrument:
The scale range of the temperature control instrument must be selected so that the
■
maximum temperature present at the probe does not exceed the scale range. Once
the switch point is exceeded, you should also be careful of any temperature rise that
occurs.
In operation, the instrument should not be exposed to any strong vibrations or shock
■
loadings.
Avoid soiling and strong fluctuations of the ambient temperature.
■
Cutting the measuring line leads to the destruction of the instrument and, thus, to a
■
shutdown.
DANGER!
Danger to life caused by electric current
Upon contact with live parts, there is a direct danger to life.
▶
CAUTION!
Damage to the instrument
Heavy shocks, oscillations and vibrations lead to imprecise values,
increased wear in the transmission mechanism, and fractures on welded
or soldered joints.
▶
12
For these media, in addition to all standard regulations, the appropriate
existing codes or regulations must also be followed.
Wear the requisite protective equipment
The instrument may only be installed and mounted by skilled
personnel.
It is essential that the remote capillary is coiled in several loops
between the last fixing point and the probe, and free from tension.
Any excess length must also be coiled, since cutting would render the
instrument unserviceable.
Operating instructions for expansion thermometer, CEDASPE
VT series
®