Temperature
TEMP ºC
(-40ºC~1000ºC)
TEMP ºF
(-40ºF~1832ºC)
Continuity and Diodes
Range
Overloading protection: 600V DC or AC effective value.
Precautions before operation:
1.
Press the POWER switch to check 9v battery. In case of lower battery voltage level, "
will be shown on the display. In this case, you need to replace the battery.
2.
"
" symbol near the input terminals means that input voltage or current shall not exceed
the indicated value so that the internal circuits can be protected from damage.
3.
Prior to the testing, the functional switch shall be placed at the needed range.
4.
Multimeter Description:
16
Range
-40ºC~0ºC
0ºC~400ºC
400ºC~1000ºC
-40ºF~32ºF
32ºF~752ºF
752ºF~1832ºF
Description
Display the farward voltage of diode
(approximate value), unit "mV"
Resistances ≤10Ω, the buzzer sounds;
>10Ω, the buzzer doesn't
necessarily sound;
Display approximate resistance
value, unit: Ω.
OPERATING METHOD
Resolution
1ºC
2ºF
Forward DC current about 1 mA
Reverse DC voltage about 2.8 V
Open circuit voltage about 2.8V
1. Power switch.
2. LCD display.
3. Data hold.
4. Rotary switch.
5. Input Terminals.
Accuracy
±(3%+9)
±(1%+5)
±(2%+10)
±(3%+10)
±(1%+8)
±(2%+18)
Testing conditions
"