1.- BUILDING-IN.
The water heater shall be built-in as close as possible to the outlets in order to reduce the heat loses.
The building place must be chosen considering the maximum reduction of 90º elbows in water connections
and, at the same time, make easy the substitution of the heating element.
2.- APPLIANCE WALL HANG
Due to its particular design, the APARICI electrical water heaters could be installed in two positions as you
could see at fig-2.1 and 2.2:
1. Vertical. At this position cold water inlet pipe (F) is on the right side and hot water outlet pipe (C) on the left
side. The hydraulic safety valve supplied with the appliance must be installed at the inlet cold water pipe
(F).
2. Horizontal with maintenance cover on left side. In this case inlet cold water pipe (F) will be placed every
time in the bottom pipe and hot water outlet pipe (C) in the upper part. The safety valve must be installed
TYPE
S075
G1/2'
WATER INTLET
AND OUTLET
DIAMETER
Ø450
A
813
B
470
C
450
D
VERTICAL /
HORIZONTAL
D - UNIVERSAL
VERTICAL
210 - 440
POSITION
E
F