7.
Troubleshooting
7.1.
Fault indication in the display
Repair and maintenance work must only be carried out by Klafs service personnel or
those who are expressly authorized by Klafs to perform such work!
The fault message appears near the two right
digits of the bathing duration display (e.g. 91).
Service
The
symbol flashes together with the
fault message.
Service
As long as the
control unit is operable.
The fault message is displayed alternately with the
bathing program.
No. Error
91
The touch sensitive switch (SKS) has triggered. Remove the object from the cover over the
95
Line break actual temperature sensor.
96
Line break heater temperature sensor.
97
Safety thermostat (STB) disconnected.
98
Short-circuit actual temperature sensor.
99
Short-circuit heater temperature sensor.
5070178/07.02
symbol flashes, the
Eliminate error
heater.
Disconnect the control unit from the mains.
Dis onne t the ontrol unit from the mains
Do not operate the sauna any more!
Do not operate the sauna any more!
Inform the servicing personnel at Klafs.