Balanced Circuit
12
Input Overcurrent
Auxiliary Power
13
Undervoltage
14
DC Component Exception
15
16
PV Connection Error
17
PV1 Overcurrent
18
PV2 Overcurrent
19
20
PV1 Voltage High
21
PV2 Voltage High
22
23
PV1 ISO Failure
24
PV2 ISO Failure
25
26
Hardware PV1 Failure
27
Hardware PV2 Failure
28
29
GFCI Hardware Circuit Failure
30
31
Phase Sequence Error
32
33
Zero Drift Anomaly
34
Hardware Input Overcurrent
Relay Failure
GFCI Failure
Fan Failure
Turn off the inverter and wait 30 minutes
to restart up it. If the symptom persists,
please contact the BLUETTI support team.
Turn off the inverter and wait 30 minutes
to restart up it. If the symptom persists,
please contact the BLUETTI support team.
Check if the total voltage of solar panels
exceeds the limit. Reduce the number of
solar panels and the inverter resumes
operation after calibration.
Check the insulation resistor between solar
array and grounding for a short circuit.
Turn off the inverter and wait 30 minutes
to restart up it. If the symptom persists,
please contact the BLUETTI support team.
Check if the AC output PE wire is
grounded.
Check if the grid connection meets
installation requirements.
Check if the inverter fan operates well.
Turn off the inverter and wait 30 minutes
to restart up it. If the symptom persists,
please contact the BLUETTI support team.
75