Change the batteries
Before changing the batteries, remember to deactivate
your system and read the instructions below.
Key fob
1
2
Remove the screw and then the cover of your key fob,
and replace the battery (1x 3 V Lithium Panasonic or
Energizer CR2032).
IntelliTAG®
Open the cover and replace the battery
(1x 1,5 V alkaline AAA).
Indoor motion sensor
Open the cover and replace the battery
(1x 3 V Lithium CR123A).
Indoor siren
Open the siren cover in the direction
indicated by the arrow, remove the battery
protection cover and replace the batteries
(4 x 1.5 V alkaline D).
Outdoor siren
1
2
Deactivate the tamper protection
from the wall using a screwdriver (hold down and turn in the
direction of the arrow). Open the battery cover and replace the
batteries (4 x 1.5 V alkaline D).
Go to the application's "My devices" menu.
(1)
14
and then remove the siren
(1)
Technical information
Link Essential:
• Connectivity: Wi-Fi 802.11 b/g/n Open, WPA, WPA2-Personal, WPA-
WPA2 mixed mode, WPA3 (2.4 GHz, e.r.p<100 mW)| Proprietary protocol
(2.4 GHz, e.r.p<100 mW) | Radio Somfy Protect (868 MHz-870 MHz,
e.r.p<25 mW) | LPWA (868 MHz, e.r.p<25 mW) | Somfy Around
emergency network in the event of Internet outage.
• Indoor use only | Maximum installation height: 2 m | Cannot be installed
at an altitude of more than 2,000 m.
• Security: Continuous monitoring of the radio connection between
system components | Radio interference detection on detectors and
sirens (sending an alert to the user) | Encryption of radio communications |
Tamper protection
• Detection of power cuts and autonomy on rechargeable battery (24 hours).
Autonomy calculated on new battery.
• Power supply: Mains unit: Use only the mains unit supplied with the
product (Input: 100-240 V AC, 50- 60 Hz, 0.5 A max/Output : 5 V ―1 A)
|Lithium battery: 2 Ah. The battery can only be replaced with a Somfy
compatible battery ref 1875294 and by following the instructions men-
tioned in the box of the replacement product.
• Size: 160 x 28 mm | Weight: 340 g | Operating temperature:
Key fob: Proprietary protocol (2.4 GHz, e.r.p<100 mW) | Battery life under
normal use: 1 year (1x 3 V Lithium CR2032) | Size: 34 x 10 mm | Weight: 12 g
| Operating temperature: 0-45° C
IntelliTAG®: Radio range with Link Essential: 200 m in open air | Radio
Somfy Protect (868 MHz-870 MHz, e.r.p<25 mW) | Indoor and outdoor
use (IP54) on all types of leaves| Battery life under normal use: 1 year (1x
1.5 V alkaline AAA / LR03) | Tamper protection | Size: 60 x 28 x 13.5 mm |
Weight: 28 g | Operating temperature: 0-45° C
Indoor motion sensor: Radio range with Link Essential: 200 m in open air |
Radio Somfy Protect (868 MHz-870 MHz, e.r.p<25 mW) | Battery life under
normal use: 2 years (1x 3 V Lithium CR123A) | Tamper protection |
Size: 47 x 47 mm | Weight: 55 g | Operating temperature: 0-45° C
Indoor siren: Radio range with Link Essential: 200 m in open air | Radio
Somfy Protect (868 MHz-870 MHz, e.r.p<25 mW) | Battery life under
normal use: 2 years (4 x 1.5 V alkaline D / LR20) | Tamper protection |
Size: 175 x 45 mm | Weight: 985 g | Operating temperature: 0-45° C
Outdoor siren: Radio range with Link Essential: 200 m in open air | Radio
Somfy Protect (868 MHz-870 MHz, e.r.p<25 mW) | Outdoor use (IP43) |
Battery life under normal use: 2 years (4 x 1.5 V alkaline D / LR20) | Tamper
protection | Size: 220 x 55 mm | Weight: 1,200 g | Operating temperature:
-10° / 45° C
Recycling and scrapping
Ensure batteries are separated from other types of waste and are recycled via your
local recycling centre.
We care about our environment. Do not dispose of the appliance with usual
household waste. Give it to an approved collection point for recycling.
Meaning of the logos mentioned on the product
This product must only be installed in a sheltered, dry location.
This product incorporates double electric insulation and therefore does not require
any connection to the earth conductor.
Direct current
Alternating current
Safety isolating transformer, short-circuit proof
If the cover is lost, please contact us so that it can be replaced with a compatible
cover. Risk of explosion if the battery or batteries are replaced by an incorrect type.