3.5Thecompressorstopswhileworking
· The motor has an automatic resetting thermal protection, that stops the compressor
when the temperature is too high. The compressor will start again automatically after
15/20 minutes.
·
3.6Airleaks
· Can be due to bad seal of any connection, check all connections wetting with suds
·
3.7Leakfromthevalveplacedunderthepressureswitch
· Damaged valve, replace it.
· The defect can be due to an unperfect valve seal (See point 3.1d).
3.8Thecompressorstartswhennoairisbeingtapped
· Air leak (See point 3.6).
5.9Thecompressorstartsandstopsmorefrequentlythanusual
· a) Large amount of condensate in air tank. Remove condensate.
· b) Air leak (See point 3.6).
3.10Thecompressordoesnotswitchonwhenpressureisundertheminimumlevel
and/ordoesnotswitchoffatmaxpressure
· Defective pressure switch. Replace.
3.11Thecompressorgetsveryhot
· a) Air leak (See point 3.6).
· b) Clogged intake filter. Clean or replace.
· c) Too high outsidet temperature. Do not close the unit in a cupboard unless ade-
quately ventilated.
· d) Over-running.
Ensure the compressor is the correct model for your work load.