Descargar Imprimir esta página

Hella Gutmann MT-HV Manual De Instrucciones página 45

Ocultar thumbs Ver también para MT-HV:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 111
MT-HV
4.6
User Communication
Meaning of the LEDs with different interactions:
When the MT-HV is switched off and you briefly push ON/OFF, the yellow LED
will light up until the start procedure is completed.
After the start procedure is completed, the LED is permanently green and
the MT-HV is ready for operation.
When the MT-HV is switched on and you briefly push ON/OFF, the green LED
will flash several times until the MT-HV is shut down entirely.
If the connection is inactive or if there is no connection in battery mode, the MT-
HV will switch off after 2 minutes. Before that the red LED will light red for 60
seconds.
If an update is in progress, the LED will flash several times green until the
update is finished.
The green LED is permanently on if the high-voltage measurement is active.
The yellow LED is permanently on if high voltage is switched to the test prods.
The blue LED is permanently on if the MT-HV has Bluetooth® connection.
Explanation of the battery status display:
more than 40 % of entire charge
The battery status indicator flashes green if the battery is being charged.
The status indicator is permanently green if the battery is fully charged.
20 % to 40 % of entire charge
20 % or less (charging required!)
The battery status indicator flashes red if battery charge is less than 10 %.
I I n n t t e e r r a a c c t t i i o o n n
Device Description
User Communication
EN
L L E E D D
45

Publicidad

loading