o DMX512 Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start address
is the channel number from which the device starts to "listen" to the DMX controller. Enter the correct number and read it
from the display located on the base of the VDPL1501MHS-B / VDPL1501MHS-W.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the VDPL1501MHS-Bs / VDPL1501MHS-Ws will "listen" to the control signal
on one particular channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you
set different addresses, each device will "listen" to a separate channel number. Changing the settings of one channel will
only affect the device in question.
In the case of the 13-channel VDPL1501MHS-B / VDPL1501MHS-W, you will have to set the start address of the first
VDPL1501MHS-B / VDPL1501MHS-W to 1, the second VDPL1501MHS-B / VDPL1501MHS-W to 14 (1 + 13), the third to
27 (14 + 13) and so on.
7. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing) should not be
deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not change the location of the
connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
8. Technical Specifications
Power Supply
Power Consumption
Fuse
LEDs
Beam Angle
Illuminance
Dimensions
Total Weight
Max. Ambient Temperature
Max. Housing Temperature
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or
injury resulted from (incorrect) use of this device. For more info concerning this product, please visit our website
www.hqpower.com. The information in this manual is subject to change without prior notice.
VDPL1501MHS-B / VDPL1501MHS-W_v4
max. 230 VAC / 50 Hz
50 W
F2A, 250 VAC (5 x 20 mm) (order code FF2N)
1 x 15 W Lamina
®
13°
1,380 lux
173 x 173 x 249 mm
3.8 kg
45°C
60°C
8
HQPOWER