ISSUE CHECKLIST
PROBLEM
Pilot will not light
Pilot will not light
Pilot will not stay
Pilot will not
on
stay
Pilot will not
stay
Burner will not
light
PROBABLE CAUSE
Gas valve may be OFF
LPG cylinder empty
Orifice blocked
Air in supply system
Loose connection
Debris around pilot
Loose connection
Thermocouple damaged
Gas leak in line
Lack of gas pressure
Gas pressure is low
Orifice blocked
Control knob not ON
Thermocouple damaged
Pilot light assembly bent or not in
correct location
SOLUTION
Turn the gas valve ON
Refill LPG cylinder
Clean or replace Orifice
Purge air from lines
Check all fittings
Clean dirty area
Tighten connection
Replace Thermocouple
Check connections
LPG cylinder is near empty
LPG cylinder is near empty
Remove, clean and replace
Turn knob to ON
Replace Thermocouple
Place pilot light in correct Position
and retry
46