Note: Depending on the condition of the battery, the charger adapts the charging currents to ensure
optimum charging of the battery. Only during the main charging phase, the battery is charged with the
maximum charging current. Shortly before the maximum charging capacity has been reached the
charging current is reduced. This ensures a gentle and best possible charging up to the battery's
maximum capacity.
Item
10
2.6A, 270 seconds; then 20A, 30 seconds. That means the charger charges the battery 270
seconds on the first part to warmup the battery, then charges it 30 seconds with extremely high
current to "bump' up the battery. After that the charger will go to standby status and can be
Description
Wrong Polarity: This symbol flashes if a battery was connected in reversed
polarity. Check the polarity and connection and reattach the charging
cables.
Defective-Battery:
-
As soon as the battery charger has been connected to the mains,
the charger analyses the connected battery: If the battery voltage is
lower than 2.0 V or higher than 28 V, the battery is not suitable or
defective and the "Defective-Battery"-symbol lights up.
-
If the connected battery is charging in "RECOVER-12V"-Mode and
after 3 hours the battery´s voltage is still not higher than 12V the
battery is also considered as defective.
Not Connected: This symbol flashes if no battery is connected or the
connection is interrupted. Check the connection and reattach the charging
cables.
Battery-level:
This symbol will flash during the charging process. The bars indicate the
progress:
1 bar (20%), 2 bars (40%), 3 bars (60%), 4 bars (80%), 5 bars (90%)
If the symbol stops flashing, the battery is considered as fully charged and
the charger will switch automatically to "Maintenance / Trickle charging" to
keep the battery in a fully charged state.
JUMP CHARGE = Boost Charge
charged in a normal way.