Charging
Your Pro-User IBC charger can easily be configured to charge many different types of batteries.
The
following recommendations should, however, only be seen as guidelines. When in doubt, always consult
the battery manufacturer for further instructions.
Starting the charging process:
1. Once you have established that the battery clamps or eyelets have been correctly
connected, you can start the charging process. To do so, insert the charger plug into the
AC socket.
2. The charger will start in Standby mode, indicated by the STAND BY LED.
3. Press the mode button to select the appropriate charge mode (press and hold for three
seconds to enter an enhanced charge mode) for the voltage and chemistry of your battery.
The selected charge mode LED will illuminate.
Charging Modes.
The IBC15000B has nine (9) modes. The Lithium and Recover charge modes require the mode
button to be pressed and held for three (3) seconds to enter the enhanced mode. These "Enhanced"
modes require your full attention before selecting.
NEVER USE RECOVER MODE ON LITHIUM IRON PHOSHATE BATTERIES.
Do not operate the charger until you confirm the appropriate charge mode for your battery.
Below is a brief description:
Converts to a DC power supply for powering any 12V DC device. When selected, 13.6V LCD will
Charging Modes
For charging 12-volt Flooded, Gel, Maintenance-Free batteries.
14.5V
For charging 12-volt batteries in cold temperatures below 50°F (10°C) or AGM batteries. When
14.7V
For charging 24-volt Flooded, Gel, Maintenance-Free batteries. When selected, the LCD will
29V
For charging 24 volt batteries in cold temperatures below 50°F (10°C) or AGM batteries. When
29.4V
For charging 12 volt advanced AGM batteries that require a higher than normal charge voltage.
When selected, the LCD will illuminate.
15V
For recovering and repairing and storing, old, idle, damaged stratified or sulfated Flooded, Gel,
Maintenance-Free Lead Acid batteries. When selected, the LCD will illuminate.
NEVER USE RECOVER MODE ON LITHIUM BATTERIES
14.7V
For charging 12.8-volt lithium iron phosphate batteries. When selected, the LCD will illuminate.
14.5V
12V NORM
15A
12V COLD/AGM
selected, the LCD will illuminate.
15A
24V NORM
illuminate.
7.5A
24V COLD/AGM
selected, the LCD will illuminate.
7.5A
12V AGM+
15A
12V RECOVER
Press & Hold Mode
2.6A
12.8V LITHIUM
Press & Hold Mode
15A
13.6V Power Supply
illuminate
50-400Ah Batteries
50-400Ah Batteries
25-200Ah Batteries
25-200Ah Batteries
50-400Ah Batteries
50-400Ah Batteries
30-200Ah Batteries