Descargar Imprimir esta página

Globmatic FENIX II Manual De Utilización página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

16
GLOBMATIC
|
WWW.TEDAYC.COM
PROGRAMMING
07
OT200 / OT210
7.1
SIMPLE MODE
The operator comes from the factory without programming
the travel limits. On first use, it starts with a programming
request (RIGHT LED is on)
[  ] OPEN
[  ] SELECT
[  ] CONFIRM
[  ] CLOSE
RIGHT LED
LEFT LED
To start the programming procedure for opening and closing
stroke, simultaneously press and hold [  ] and [  ], until
the nightlight flashes five times.
7.1.1
DEFINE THE OPEN POSITION
RIGHT LED
displays the opening procedure:
Note: If the right LED does not flash, please
check point 9.3.
Press [  ] to move the door in the opening direction.
Press [  ] to move the door in the closing direction.
Press and hold [  ] o store the final opening position.
7.1.2
DEFINE THE CLOSE POSITION
LEFT LED
displays the closing procedure:
Press [  ] to move the door in the opening direction.
Press [  ] to move the door in the closing direction.
Press and hold [  ] o store the final closing position.
After storing the final closing position, the FENIX operator
will perform an opening cycle and a closing cycle in order to
obtain the motor effort map.
The programming of the opening and closing
courses is complete. The FENIX operator is in
Standby mode.
7.2
ADVANCED MODE
DISPLAY
[UP] INCREASE
[SET] SELECT
[DW] DECREASE
0.0.
0.0.
Press and hold [SET] until
9.9.
9.9.
Press [UP] or [DW] until
0.0
0.
0 .
.
New programming inactive.
0.
0.1
1 .
.
Re-program.
[SET] Press and hold to confirm.
7.2.1
DEFINE THE OPEN POSITION
The display shows the close procedure:
Press [UP] to move the door in the open direction.
Press [DW] to move the door in the close direction.
Press and hold [SET] to store the final close position.
7.2.2
DEFINE THE CLOSE POSITION
The display shows the close procedure:
Press [UP] to move the door in the open direction.
Press [DW] to move the door in the close direction.
Press and hold [SET] to store the final close position.
After storing the final close position, the FENIX operator will
perform an open cycle and a close cycle in order to calculate
the motor effort map.
The programming of the open and close
courses is complete. The FENIX operator will
now be in Standby mode.
Note: With the operator in standby mode, the
[UP] button serves as a START impulse.
MENU
08
8.1
ENTER MENU
FENIX operator in Standby.
Press and hold [SET] until
Press [UP] or [DW] until the desired function is displayed:
0.0.
0.0.
0.1. 0.1.
Mode of Operation
0.2.
0.2.
Automatic Closing
0.3.
0.3.
Fast Closing
0.4.
0.4.
Force Levels
1.0.
1.0.
Opening Speed
1.1. 1.1.
Closing Speed
2.0.
2.0.
Pre warning Light
2.1.
2.1.
Duration of the Courtesy Light
2.2.
2.2.
Courtesy Light Intensity
9.0.
9.0.
Number off Cylces
9.1.
9.1.
Setting the Maintenance Cycle Counter
9.2.
9.2.
Maintenance Cycles
9.7.
9.7.
Factory Reset
9.8.
9.8.
Calibrate Force Map
9.9.
9.9.
New Programming
[SET] Press and hold to confirm.
Press [UP] or [DW] to scroll forward and backward,
respectively, in the available parameters.
[SET] Press and hold to confirm.
8.2
EXIT MENU
Press and hold [SET] until 0.0. is displayed.
[SET] Press and hold to leave the menu.
FENIX operator in Standby.
Note: the menu disappears after 15 seconds of inactivity
8.3
MENU STRUCTURE
0.1. 0.1.
OPERATING MODE
0.
0.1
1 .
.
Smart Step-by-Step Mode – In this mode, if the door
is displayed.
is in the open cycle and receives a START impulse, the door
will stop. If the door is closing, after a START impulse, it will
is displayed.
stop and reverse direction until fully open.
0.2
0.
2 .
.
Step by Step Mode – In this mode, the operator only
operates on user order. For each order given, the operator
performs the following operation order:
Open->Stop->Close->Stop->Open->Stop->...
0.
0.3
3 .
.
Condominium mode – In this mode it is mandatory to
use safety systems (photocells or similar), since the operator
will proceed to the automatic closing of the door, whenever
the door is open, and immediately after the automatic closing
time elapses. In this mode, if the door is opening, it does
not allow a stop in the middle. If the door is open, each time
you give a close command it will renew the automatic closing
time. Thus, the door will not start closing until the automatic
closing time has elapsed. If the door is closing, after a START
impulse, the door will stop the downward movement and
reverse direction.
[SET] Press and hold to confirm.
0.2.
0.2.
AUTOMATIC CLOSING
0.
0.0
0 .
.
Automatic locking inactive.
0.5
0.
5 .
.
Minimum automatic close time: 5 seconds
5 5 .
. 5
5 .
.
Maximum automatic close time: 5 minutes
[SET] Press and hold to confirm.
Note: From 0 to 1min, the display shows 5 sec. increments.
From 1min to 5min, the display shows 10 sec. increments.
0.3.
0.3.
FAST CLOSING
0.0
0.
0 .
.
Quick close inactive.
0. 0.1
1 .
.
Minimum fast closing time: 1 second
0.
0.9
9 .
.
Maximum rapid closing time: 9 second
[SET] Press and hold to confirm.
0.0.
0.0.
appears on the display
.