0.4.
0.4.
FORCE LEVELS
0.1
0.
1 .
.
Force level 1. This is the most sensitive level.
0.5
0.
5 .
.
Force level 5. This is the least sensitive level.
[SET] Press and hold to confirm.
Note: The display shows 1 force level increments.
1.0. 1.0.
OPENING SPEED
Note: the gate must be closed.
0.1
0.
1 .
.
Speed 1. This is the lowest speed level.
0.5
0.
5 .
.
Speed 5. This is the highest speed level.
[SET] Press and hold to confirm.
Note: The display shows 1 force level increments.
The FENIX operator does the following tasks:
1. Performs an opening cycle
2. Performs a closing cycle
3. New closing speed assigned
1.1.
1.1.
CLOSING SPEED
Note: the gate must be closed.
0.1
0.
1 .
.
Speed 1. This is the lowest speed level.
0.5
0.
5 .
.
Speed 5. This is the highest speed level.
[SET] Press and hold to confirm.
Note: The display shows 1 force level increments.
The FENIX operator does the following tasks:
1. Performs an opening cycle
2. Performs a closing cycle
3. New closing speed assigned
2.0.
2.0.
PRE WARNING LIGHT
0.
0.0
0 .
.
Inactice pre warning light.
0.1
0.
1 .
.
Actice pre warning light.
[SET] Press and hold to confirm.
Note: This option activates the lights 3 seconds before the
movement starts.
2.1. 2.1.
DURATION OF THE COURTESY LIGHT
1
1 .
. 0
0 .
.
Minimum time of courtesy light: 10 seconds
5
5 .
. 0
0 .
.
Maximum time of courtesy light: 5 minutes
Note: The display shows 10 second increments.
[SET] Press and hold to confirm.
2.2.
2.2.
COURTESY LIGHT INTENSITY
0.
0.1
1 .
.
Intensity 1. This is the lowest intensity level.
0.
0.5
5 .
.
Intensity 5. Este é o nível de intensidade mais alto.
Note: The display shows 1 force level increments.
[SET] Press and hold to confirm.
9.0.
9.0.
NUMBER OF CYLES
The display shows the number of cycles the FENIX operator
as concluded, in a sequence of digits, from the most
significant digit to the least significant digit, exemple: number
of cycles: 12345
1 1 > > 2 2 > > 3 3 > > 4 4 > > 5 5
9.1. 9.1.
DEFINE THE NUMBER OF CYCLES FOR MAINTENANCE
0.1
0.
1 .
.
Minimum number of cycles for maintenance notification:
1x1000. Note: The actual value corresponds to the value
shown in the display times 1000 (1x1000)=1000 cycles for
the maintenance warning.
9 .
9
. 9
9 .
.
Maximum number of cycles for maintenance notification:
99x1000. Note: The actual value corresponds to the value
shown on the display times 1000 (99x1000)=99000 cycles
for maintenance notification.
[SET] Press and hold to confirm.
9.2.
9.2.
NUMBER OF MAINTENANCE CYCLES
The display shows the number of cycles for maintenance
notification in a sequence of digits, from the most significant
digit to the least significant digit, exemple: number of cycles:
12345
1 1 > > 2 2 > > 3 3 > > 4 4 > > 5 5
9.7.
9.7.
FACTORY RESET (Original settings)
Note: the opening and closing point will not be changed
0.0
0.
0 .
.
Factory reset inactive.
0.1
0.
1 .
.
Do a factory reset.
[SET] Press and hold to confirm.
9.8.
9.8.
CALIBRATE FORCE MAP
Note: the gate must be closed.
0.0
0.
0 .
.
New calibration inactive.
0.1
0.
1 .
.
Do a new calibration.
[SET] Press and hold to confirm.
The FENIX operator does the following tasks:
1. Performs an opening cycle
2. Performs a closing cycle
3. New closing speed assigned
9.9.
9.9.
NEW PROGRAMMING
0.
0.0
0 .
.
New programming inactive.
0.1
0.
1 .
.
Do a new programming.
[SET] Press and hold to confirm.
See points procedure 7.2.1 and 7.2.2
AFTER INSTALLATION
09
9.1
STOPPER IN THE OPENING
After programming
and with the gate fully
open, place the stop
5mm from the carriage.
9.2
PROGRAM THE REMOTES
SIMPLE MODE
9.2.1
FROM THE OPERATOR'S COVER
Press and hold [  ], until the presence light flashes twice, to
start programming the receiver's channel 1.
The RIGHT LED indicates
Programming channel 1:
While the courtesy light is on (factory setting for 8 seconds
timeout), the receiver is in programming mode, ready to
capture new remotes on channel 1.
To program the transmitter, simply press the button of the
transmitter you wish to program, if the code is accepted the
operator courtesy light will flash 3 times, however, if the code
is already saved in the receiver's memory, the courtesy light
will flash 6 times with a faster cadence.
The LEFT LED indicates
Programming channel 2:
While the courtesy light is on, on (factory setting for 8
seconds timeout), the receiver is in programming mode for
new transmitters on channel 2.
To program the transmitter, simply press the button of the
transmitter you wish to program, if the code is accepted the
operator courtesy light will flash 3 times, however, if the code
is already saved in the receiver's memory, the courtesy light
will flash 6 times with a faster cadence.
Each time the receiver programs a new transmitter, it will
automatically renew the 8 seconds timeout.
If the same code is programmed more than 3 times in
succession, the receiver will exit the programming procedure. To
program a new transmitter, you must start the process again.
WWW.TEDAYC.COM
9.2.2
ADVANCED MODE
Press and hold START RX to begin programming channel
1 on the receiver.
The RX 1 LED indicates programming channel 1.
While RX 1 LED is on (factory setting for 8 seconds timeout),
the receiver is in programming mode for new transmitters
on channel 1.
To program the transmitter, simply press the button of the
transmitter you wish to program, if the code is accepted, the
RX1 LED will flash 3 times, however, if the code is already
stored in the receiver's memory, the RX1 LED will flash 6
times with a faster cadence.
The RX2 LED indicates the programming of channel 2.
While RX2 LED is on (factory setting for 8 seconds timeout),
the receiver is in programming mode for new transmitters
on channel 2.
To program the transmitter, simply press the button of the
transmitter you wish to program, if the code is accepted, the
RX2 LED will flash 3 times, however, if the code is already
stored in the receiver's memory, the RX2 LED will flash 6
times with a faster cadence.
Each time the receiver programs a new transmitter, it will
automatically renew the 8 seconds timeout.
If the same code is programmed more than 3 times in
succession, the receiver will expire the programming
procedure. To program a new transmitter, you must start the
programming process again.
5mm
NEW PROGRAMMING OF THE OPENING AND
9.3
CLOSING STROKES - FROM THE OPERATOR'S
COVER
Press and hold [  ] and [  ] simultaneously, until the
courtesy light flashes five times, to start programming the
opening and closing cycles.
See points procedure 7.1.1 and 7.1.2
9.4
OCCURRED FAILURES
The display shows a sequence of faults that have occurred,
for example:
99 -> 97 -> 97 -> 88 -> ...
9.5
RESETTING STORED FAULTS
0.
0.0
0 .
.
Fault reset inactive.
0.1
0.
1 .
.
Do a fault reset.
DESCRIPTION OF FAULT
10
CODES / EVENTS
F-99 Event: STOP button active
F-98 Event: Active photocell
F-97 Event: Force overload in close procedure
F-96 Event: Force overload in open procedure
F-95 Fault: Motor Faulty
F-94 Fault: Encoder defective
F-93 Fault: Memory faulty
F-92 Fault: auxiliary module defective
F-91 Fault: Door is not at minimum height
F-90 Fault: Door exceeds maximum height
F-89 Event: Overload sequence during close procedure
F-88 Fault: Power failure
F-87 Event: Maximum force reached
F-86 Event: Maintenance Notice
17
|
GLOBMATIC
LED RX1
START RX
LED RX2

Publicidad