FUNCTIONAL
DESCRIPTION
CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before adjusting or checking function on the tool.
Installing or removing battery
cartridge
Always switch off the tool before
CAUTION:
installing or removing of the battery cartridge.
CAUTION:
Hold the tool and the battery car-
tridge firmly when installing or removing battery
cartridge. Failure to hold the tool and the battery
cartridge firmly may cause them to slip off your hands
and result in damage to the tool and battery cartridge
and a personal injury.
► Fig.3: 1. Red indicator 2. Button 3. Battery cartridge
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator as
shown in the figure, it is not locked completely.
CAUTION:
Always install the battery cartridge
fully until the red indicator cannot be seen. If not,
it may accidentally fall out of the tool, causing injury to
you or someone around you.
CAUTION:
Do not install the battery cartridge
forcibly. If the cartridge does not slide in easily, it is
not being inserted correctly.
NOTE: The tool does not work with only one battery
cartridge.
NOTE: Pay attention to the position of your fin-
gers when installing the battery. The button will be
depressed unintentionally.
Tool / battery protection system
The tool is equipped with a tool/battery protection sys-
tem. This system automatically cuts off power to the
motor to extend tool and battery life. The tool will auto-
matically stop during operation if the tool or battery is
placed under one of the following conditions.
Overload protection
When the tool is operated in a manner that causes it
to draw an abnormally high current, the tool automat-
ically stops and the main power lamp will blink. In this
situation, turn the tool off and stop the application that
caused the tool to become overloaded. Then turn the
tool on to restart.
Overheat protection
When the tool is overheated, the tool automatically
stops and the capacity indicator lamp will blink as illus-
trated. In this situation, let the tool cool down before
turning the tool on again.
Capacity indicator status
On
Overdischarge protection
When the battery capacity becomes low, the tool stops
automatically. If the product does not operate even
when the switches are operated, remove the batteries
from the tool and charge the batteries.
Indicating the remaining battery
capacity
► Fig.4: 1. Check button 2. Capacity indicator
The remaining battery capacity is shown while you
are pressing the check button. The capacity indicators
correspond to each battery.
Capacity indicator status
On
Indicating the remaining battery
capacity
Only for battery cartridges with the indicator
► Fig.5: 1. Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
13 ENGLISH
Off
Blinking
Off
Blinking
Status
Overheated.
Remaining
battery
capacity
50% to 100%
20% to 50%
0% to 20%
Charge the
battery

Publicidad