WIRING INSTRUCTIONS WITH CAT5 WIRE
Fit the CAT5 wire in a RJ45 plug with Urmet logo:
Insert the wire in the guide respecting the colour coding shown (Standard T568B).
Cut the wires which protrude from the guide by approximately 5 mm, insert the guide in the plug and
crimp the plug with a specifi c tool.
Make sure that the grey sheath remains inside the plug.
This type of connection DOES NOT ensure double insulation.
TECHNICAL SPECIFICATIONS
POWER VOLTAGE AND CONSUMPTION ON TERMINALS V+ V-
Power voltage: ...............................................................................................................................44 ÷ 57 Vdc
Current consumption during video call @48 V: ....................................................................................200 mA
Current consumption in standby @48 V: ..............................................................................................140 mA
Working temperature range: .................................................................................................. -10 °C ÷ +50 °C
Relay contact range C, NC, NO:
Maximum switching voltage: ................................................................................................................ 30 V
Maximum switching current: ...............................................................................................................3,5 A
Maximum switching load: ......................................................................................................... 40 VA 25 W
Max. distance from hall button: .............................................25 m with cable cross-section area 0.5 mm
Max. distance from open door sensor: .................................50 m with cable cross-section area 1.5 mm
Max. distance from supplementary power supply: .............100 m with cable cross-section area 1.5 mm
Max. distance from capacitance lock: ................................100 m with cable cross-section area 1.5 mm
DS1039-053A
All manuals and user guides at all-guides.com
Wire
No.
1
2
1
3
4
8
~ 5 mm
1
8
Wire colour
White-Orange
Orange
White-Green
Blue
1
8
Wire
Wire colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
Plug
2
2
2
2
9

Publicidad

loading