LED Indicators
• Blue LED indicates the switching unit is powered by 230 V AC. If the unit is not con-
nected to power or if the main switch is in the OFF position, the blue LED is not lit.
• Red LED is lit while the heating/air-conditioning system is active.
Main Switch
If the heating/air-conditioning system is not used for an extended period of time, it is
recommended to turn the switching unit off (move the main switch to the OFF position).
INSTALLATION
Pairing the Control Unit with the Switching Unit
Pairing enables transmission of information between the control unit and the switch-
ing unit.
The units pair automatically (self-learning) after pressing the "ID" button.
Attention: When pairing two or more receivers, it is necessary to have pairing
mode activated on all receivers simultaneously!
1. Insert 2× 1.5 V AA batteries into the control unit (make sure polarity of the batteries
is correct). Use alkaline batteries only, not rechargeable ones.
2. Connect the switching unit correctly to the power source, and press and hold the
"ID" button; the top red LED starts flashing.
Long-press the screen illumination button (
seconds.
Both units will automatically pair and the
on the switching unit will stop flashing and goes out.
If the pairing of the units fails, the
Testing Wireless Communication between the Units
1. Use the
button to select a temperature a few degrees higher than the current
room temperature.
2. Wait for approximately 10 seconds or press the
3. The red LED on the switching unit will light up.
4. If the LED does not light up, move the control unit closer to the switching unit.
Press the
button to set a value which is lower than the room temperature – the
receiver must switch off.
5. Repeat steps 1 to 4.
The maximum range between the control and switching unit is 100 m in an open
space. The range may decrease indoors as the signal has to pass through walls
and other obstacles.
6. Press the "RESET" button once the test is complete.
) on the control unit within 10
icon will be displayed. The red LED
icon will be flashing instead.
button.