Problem
1. The chimney has been
1. The
overheated and the temperature
fireplace goes
limit control has been activated
out and cannot
or the circuit breaker has been
be turned on.
opened.
1. The cable is loose.
2. The flame
2. Faulty flame engine.
does not
3. Defective flame rod.
move.
3. The flame is
1. Wiring is loose
not visible
4. The game
1. Wiring is loose
of logs does
2. The embers are off
not shine.
1. The batteries are exhausted.
5. The remote
2. You are not aiming correctly.
control does
3. The remote control and/or
not work.
sensor are defective.
Possible cause
Solution
1. Follow the steps to restart the
appliance detailed in the Temperature
Limit Control section.
1. Check if the wiring has loose
connections.
2. Call a qualified maintenance
technician to replace the flame motor.
3. The flame rod is not well placed,
due to a sudden transfer or handling of
the product. To solve this problem, it is
enough to remove the glass, put the
chimney upside down, remove the
screws that hold the bottom of the
frame plate and place the flame rod
correctly.
1. Disconnect the fireplace and check
if the wiring has loose connections;
check if you can connect them.
2. Press the flame button to set the
high mode.
1. Disconnect the heater and check if
the wiring has loose connections;
check if you can connect them.
1. Change the batteries on the remote
control.
2. Point the knob at the sensor directly
behind the glass display, in the center
of the unit, just above the logs.
3. Replace the remote control and/or
sensor.