The work area should be well ventilated.
Provide adequate lighting in the work area to allow observation of the cleaning process and the floor area
around the machine. Be sure to allow adequate room to bring work to and from the machine. Provide
sufficient clearance around the machine for fluid changeovers and servicing.
Site Preparation
Before installing, careful consideration should be given to the place of operation. Place unit on a smooth,
level surface. To the extent possible avoid installing machine in areas subject to high forklift traffic.
Reasonable precautions shall be taken to avoid damaging the legs and tank walls.
Assembly
Install the Dyna-Brute/Dyna-Brute XL in a convenient location close to an electrical outlet, away from
open flame or sparks. Check and tighten all fittings before filling with solvent. Liquid level should remain
under the high-level line. Do NOT overfill. Keep cover closed when not in use to reduce evaporation of
cleaning fluid.
COMPONENT
REFERENCE
A
B
C
SCREW, 10-32NF X 1/2
D
FLAT WASHER,1/2OD,.200ID
Automatic Safety Cover
Open the lid (FIGURE 2(Z)) on your Dyna-Brute/Dyna-Brute XL and you will notice that it lifts simply and
easily with one hand. There is nothing to connect or disconnect to open or close the cover.
Your Dyna-Brute/Dyna-Brute XL lid is equipped with a two-way gas spring (FIGURE 2(E)) that also
incorporates a fusible link (FIGURE 2 (I)). When open, the cover mechanism supports the cover at a
slightly forward angle. This angle is necessary to assure the cover's fusible link will operate in the unlikely
event of fire in the tank. In the event of a fire, the fusible link will melt at 165°F permitting the lid to slam
shut, reducing oxygen supply to the fire.
795-93884
INSTALLATION AND OPERATION
DESCRIPTION
Tank Assembly
LEG
QTY.
1
2
8
8
FIGURE 1
6 of 36
3/4/2022

Publicidad

loading

Este manual también es adecuado para:

Dyna-brute xl