THREE STAGE FILTRATION SYSTEM
The Zep Dyna Filtration system effectively removes unwanted greases and oils on a continuous basis for
more effective cleaning and longer solvent life.
Filter Baskets
The filter basket (FIGURE 2(Y)) hooks to the back of the tank, underneath the work shelf and is easily
removed for cleaning. Solvent flows from the metal flush hose (FIGURE 2(N)) or flow thru brush(FIGURE
2(M) onto the work shelf (FIGURE 2(O)) and drains through slots in the back of the work shelf into the
filter basket located at the middle rear of the tank. Heavy soils will drop to the bottom of the rectangular
container. Solvent will then flow through the filter pad (FIGURE 2(X)) and back into the tank. Keeping
the filter basket clean will prolong solvent life.
CANISTER FILTER
Replace the Zep canister filter every two months or when there is a reduction in flow rate from the spout.
DYNA-TRAP FILTER BAG
Attach the Dyna-Trap by pushing the connector hose onto the hose-barb on the spray arm assembly and
turn the "ON/OFF" switch to the ON position. Limited amounts of greases and oils are removed from
solvents as fluid percolates through the filter medium.
Work Shelf
Place the work shelf on the two mounting brackets in the tank. The drain slots on the work shelf should
be roughly centered on the filter basket below.
All models:
Never work with equipment you feel may be unsafe. Contact your supervisor immediately if you
feel a piece of equipment is in an unsafe condition.
Fill tank with Zep approved solvent cleaning fluid with flash point of 104°F (40°C) or higher. Tank
must contain enough fluid to submerge the pump but should not be filled above high-level mark.
Insert plug into a properly grounded compatible outlet.
This machine contains a flexible hose(N) and flow thru brush(M) both capable of splashing solvent
and/or ejecting it from the machine. These items must be directed into the tank at all times and
eye protection worn while operating the equipment.
Turn on rocker switch on right side of tank to start fluid recirculating.