6.8 Remote Control Operation Instructions(NO.8)
Overall display:
Off button;
Gear/temperature/item adjustment knob;
screen display area
Operating mode:
①In manual mode, the setting gear can be adjusted within the range of 1~10;
②In automatic mode, the setting temperature can be adjusted within the range of 8~36℃, and the gear
of the control switch changes with the temperature in the cab. When the temperature rises or falls, the
control switch will automatically adjust the running gear.
Quickly reach the set temperature, allowing the heater to operate more intelligently and economically.
③ When a fault occurs during operation, the fault code will be flashed on the display window of the
control switch to facilitate more accurate and intuitive finding of the fault.
Instructions:
On/Off: Press【On/Off】to turn on when the machine is off; press 【On/Off】to turn off when the
machine is on;
Mode switching: in manual mode, press and hold the [knob] for 3s to switch to automatic mode; in
automatic mode, long press [knob] for 3s to switch to manual mode;
Gear adjustment: Rotate the [knob] clockwise to run the gear/temperature +1, up to 10 gears/36℃,
Rotate the [knob] counterclockwise to run the gear/temperature-1, the minimum to 1st gear/8℃;
Engineering mode: Press [ON/OFF] [Knob] simultaneously for 3s to enter engineering mode, turn
[Knob] item +1 clockwise, press [Knob] item -1 counterclockwise,
In engineering mode, the display area displays data items;
001: Heater motherboard version number; 002: Fault code; 003: Shell temperature;
004: Power supply voltage; 005: Heater running gear;
007: Altitude; 008: Remote matching enable
Remote control matching: In the power-on state, press the [knob] 3 times continuously, the screen will
display 'rte', at this time, press any button on the remote control to match, and automatically return to
the running interface after the matching is successful;
Language switching: In the power-on state, press the [knob] continuously twice to switch, and switch
according to the sequence of 'English', 'German', 'Russian' and 'Voice off';
Oil pumping mode: Press and hold the [knob] for 7s in the off state, the display area starts to count down
for 300s and the oil pumping will start, and it will automatically exit when the countdown is over.
- English 012 -
006: Cab temperature;
7. Description of LCD E code display
LCD display Panel display
cause of issue
12V model: voltage higher than 18V
E-01
/voltage lower than 10V
24V model: voltage higher than
E-02
32V/voltage lower than 20V
E-03
Glow plug short circuit/Glow
plug open circuit
Oil pump short circuit/oil
E-04
pump open circuit
The temperature of the shell is high,
E-05
exceeding 260℃
- English 013 -
Solution
Check the power supply voltage,
external power supply
Check the power supply voltage, ex-
ternal power supply
1.
The glow plug is short-circuited or
the connection wire is reversed
2.
The insulation damage at the tail
of the glow plug causes a short
circuit
3.
Leakage of glow plug
Poor contact of the glow plug
4.
connector
The glow plug is burned out and
5.
replaced
1.
The oil pump is not connected
properly, and the connection line
of the oil pump is short-circuited or
disconnected.
2.
The pin socket control board is not
firmly inserted
3.
The oil pump circuit is disconnect-
ed and the oil pump is faulty
1.
The machine's air circulation is
obstructed, and the air inlet and
outlet are blocked, and the air
duct is blocked
2.
The installation space is too
narrow
3.
The oil pump with a large amount
of oil is connected incorrectly
4.
Oil leaking from the one-way
valve of the oil pump
5.
The sensor is damaged