Make sure that the item is installed by a competent
installer.
Shut off the main water supply.
Observe all local plumbing and building codes.
Do not fit any form of flow control in the outlet pipe
work if the shower fittings are installed in conjunction
with a product that requires the fittings to act as a
vent (e.g. an electric shower).
Dimensions below are applicable for UK water
regulations and may differ for other countries. The
position of the shower and shower fittings must
provide a minimum gap of 25 mm between the
showerhead and the spill over level of any bath,
shower tray or basin and a minimum gap of 30 mm
between the showerhead and the spill over level
of any toilet, bidet or other appliance with a Fluid
Category 5 backflow risk (see diagram).
Mixer
Shower
30 mm
Minimum
25 mm Minimum
Bath or Shower
Toilet or Bidet
FC5
SPECIFICATION
M i n i m u m m a i n t a i n e d
pressure
M a x i m u m m a i n t a i n e d
pressure
Maximum recommended
temperature
GENERAL
Zone of
25 mm
Minimum
Hand Basin
Tray FC3
FC3
0.2 bar (20 kPa)
3.0 bar (300 kPa)
60°C
au
Make sure that the item is installed by a competent
installer.
Shut off the main water supply.
Observe all local plumbing and building codes
including the Plumbing Code of Australia (PCA)
and AS/NZS 3500.
The flow regulator must be fitted as per Australian
WELS Regulations and for pressures in excess of
300 kPa.
SPECIFICATION
Minimum maintained pressure
Maximum maintained pressure
(with no flow regulator)
Maximum maintained pressure
(with flow regulator fitted)
Maximum recommended
temperature
cs
Zajistěte, aby byla součást nainstalována
kompetentní osobou.
Uzavřete hlavní přívod vody.
Dodržujte všechny lokální kódy na instalacích a
budovách.
TECHNICKÉ ÚDAJE
Minimální udržovaný tlak
Maximální udržovaný tlak
Maximální doporučená
teplota
9
GENERAL
20 kPa
300 kPa
500 kPa
60°C
OBECNÉ
0,2 bar (20 kPa)
3,0 bar (300 kPa)
60°C