Descargar Imprimir esta página

Rechner Sensors EasyTeach Manual De Instrucciones página 11

Ocultar thumbs Ver también para EasyTeach:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EasyTeach philosophy
Adjustment of the sensitivity with EasyTeach by Wire (ETW) (after switching on the supply voltage):
The EasyTeach menu starts, by activating the EasyTeach connection (Teach wire / Teach pin with the
supply voltage UB+). The menu goes through the different menu items. The desired Menu point is selected
by disconnecting the wire.
Adjustment of the sensitivity with EasyTeach by Magnet (ETM) (after
switching on the supply voltage):
The EasyTeach menu starts, by holding the teach magnet on the EasyTeach
spot. The EasyTeach spot is located next to the LEDs and is marked with
The menu goes through the different menu items. The desired menu item is
selected by removing the teach magnet.
EasyTeach menu
Output functions 1 x normally open /
1 x normally closed
Adjustment S1 = normally
open
Adjustment S2 = normally
closed
Test
Options of the output function 1 x normally open / 1 x normally closed
S1
0
S2
0
Open
A1
Closed
A2
LED green
blinking
LED yellow
Off
1
0
1
0
1
1
Closed
Open
Closed
Closed
Open
Open
Off
Off
M
EasyTeach chart
The EasyTeach charts are used for optical menu
navigation. They illustrate the flashing behaviour
of the LED and the switching of the output at the
various menu items.
EasyTeach chart
S1 = normally open / S2 = normally closed
0 = Medium / object not detected
1 = Medium / object detected
S1 = Switching point 1
S2 = Switching point 2
A1 = Output 1
A2 = Output 2
.
Adjustment S1
Initializing S1
Adjustment S2
Initializing S2
Test
11

Publicidad

loading