1. SAFETY
1.1 IDENTIFICATION OF WARNING
SIGNS
DANGER
This term defines a high-
risk hazard that can lead to
death or serious injury if not
avoided.
This
NOTICE
dangers to the machine and
its proper functioning.
Warning of a general danger.
The danger is specified by
indications in the table.
Warning about dangers due
to electrical voltage and gives
information about protection
against electrical voltage.
1.2 GENERAL POINTS
This operating and installation manual
contains important instructions to follow for
the fitting, operation and maintenance of
the Sanipump pumping station. Following
these instructions is essential for safe
operation and prevents injury and property
damage.
1.3 INTENDED USE
Only
use
the
the
applications
documentation.
• The pumping station must only be
operated in technically perfect condition.
• The pumping station must only pump the
fluids described in this documentation.
• The pumping station must never operate
without pumped fluid.
• Never exceed the usage limits defined in
the documentation.
• The safe use of the pumping station can
only be ensured when its use is compliant
(as described in this manual).
• Any alteration or modification of the
pumping station will render the warranty
void.
This operating manual must always be
available on the site so it can be accessed
by qualified staff and the operator.
Failure to comply with this operating and
installation manual will result in the loss of
warranty rights and rights to damages.
term
characterises
pumping
station
described
in
2. TRANSPORT/DISPOSAL
2.1 TRANSPORT
• Transport the pumping station in a vertical
position.
• Never hang up the pumping station by the
electric cable.
2.2 DISPOSAL
The device must not be disposed of as
household waste and must be disposed
of at a recycling point for electrical
equipment. The device's materials and
components are reusable. The disposal
of
electrical
recycling and recovery of any form
of used appliances contribute to the
preservarion of our environment.
3. DESCRIPTION
3.1 APPLICATION
Sanipump SLD 700 is a sewage and rainwater
lifting pump for all types of sewage and
rainwater, specially developed for individual
and commercial use.
It can be installed in concrete manholes or pits.
Authorised pumped fluids:
The following liquids are allowed in discharge
systems:
• wastewater: grey water and balck water
(containing faecal matter and toilet paper)
• Rain water.
Unauthorised pumped fluids:
The following liquids and substances are
banned:
• Solid materials, fibres, tar, sand, cement, ash,
in
coarse paper, hand towels, wipes, cardboard,
rubble, rubbish, slaughterhouse waste, oils,
this
hydrocarbons, greases, etc.
• Wastewater containing harmful substances
(for example, untreated greasy waste from
restaurants).
substances requires the fitting of a compliant
grease trap.
3.2 OPERATING PRINCIPLE
When the effluent level contained in the
concrete inspection chamber or the tank where
the Sanipump SLD 700 is installed is sufficient,
the sensor (e.g. float switch) triggers the lift
pump. .
The effluent is automatically lifted and flows
into the sewer.
The sewage is discharged in at least DN50 (2").
3.3 TECHNICAL SPECIFICATIONS
Sanipump SLD 700
Voltage
Frequency
Power P1
Maximum current
consumption
Speed rotation
Power cable
length
Max Height
12
and
electronic
Pumping
these
liquids
S/SA
220-240 V
50 Hz
2  0 00 W
9.2 A
2800 rpm
10 m
14.0 m
waste,
and
T
400 V
3.3 A