Descargar Imprimir esta página

GREENTIME GT-C100 Instrucciones página 27

Publicidad

Idiomas disponibles

Idiomas disponibles

who do not have the required knowledge and
technical expertise to perform the repair
operations correctly.
24. TURN OFF THE PRESSURE SWITCH
WHEN THE COMPRESSOR IS NOT USED
When the compressor is not used, turn the
knob of the pressure switch OFF, disconnect if
from the power source and open the drain cock
to discharge the compressed air from the air
tank.
25. NEVER TOUCH HOT SURFACE
To reduce the risk of burns, do not touch tubes,
heads, cylinder and motors.
26. DO NOT DIRECT AIR STREAM AT BODY
Risk of injury do not direct air stream at persons
or animals.
27. DRAIN TANK
Drain tank daily or after 4 hours of use. Open
drain fitting and tilt compressor to empty
accumulated water.
28. DO NOT STOP COMPRESSOR BY
PULLING OUT THE PLUG
Use the "AUTO/OFF" knob of pressure switch.
29.
USE
ONLY
HANDLING PARTS
ACCEPTABLE FOR PRESSURE NOT LESS
THAN 125 PSI (8.6 Bar)
Risk of bursting. Use only recommended air
handling parts acceptable for pressures not
less than 125 psi (8,6 Bar)
REPLACEMENT PARTS
When servicing use only identical replacement
parts.
Repairs
should
authorized service center.
GROUNDING INSTRUCTIONS
This compressor should be grounded while in
use to protect the operator from electric shock.
The compressor is equipped with a three-
conductor cord and three-prong grounding type
plug to fit the proper grounding type receptacle.
RECOMMENDED
be
conducted
only
The green (or green and yellow) conductor in
the cord is the grounding wire. Never connect
the green (or green and yellow) wire to a live
terminal. The green-colored rigid ear, lug, or
the like extending from the adapter must be
connected to a permanent ground, such as a
properly grounded outlet box.
EXTENSION CORD
Use only three-extension cords that have
three-prong grounding type plugs and three-
pole receptacle, that accept the compressor´s
plug. Replace or repair damaged cord. Make
sure your extension cord is in good conditions.
When using an extension cord, be sure to use
one heavy enough to carry the current your
product will draw. An undersized cord will
cause a drop in line voltage resulting in loss of
power and overheating.
Table shows the correct size to use depending
on cord length and name plate ampere rating.
If in doubt, use the next heavier gage. The
smaller the gage number, the heavier the cord.
Tab. 1 SECTION VALID FOR A MAX LENGTH OF
20 mt single-phase
CV
0,75-1
AIR
1,5
2
2,5-3
The diameter of the extension cable of the 3-phase
compressors must be in proportion to its length: see
table (tab 2)
Tab. 2 SECTION VALID FOR A MAX LENGTH OF
20 mt three-phase
CV
2-3-4
5,5
7,5
by
10
WARNING
Avoid electrical shock hazard. Never use this
compressor with a damaged or frayed electrical
cord or extension cord. Inspect all electrical
cords regularly. Never use in near water or in
any environment where electric shock is
possible.
kW
20/230V
mm2
0,65-0,7
1,5
1,1
2,5
1,5
2,5
1,8-2,2
4
Kw
220/230V
mm2
1,5-2,2-3 2,5
4
4
5,5
6
7,5
10
110/120V
mm2
2,5
4
4-6
/
380/400V
mm2
1,5
2
2,5
4